Multiphase-multistep gadolinium-enhanced MR angiography of the abdominal aorta and runoff vessels

被引:40
作者
Schoenberg, SO
Londy, FJ
Licato, P
Williams, DM
Wakefield, T
Chenevert, TL
机构
[1] Univ Michigan, Dept Radiol, Ann Arbor, MI 48109 USA
[2] German Canc Res Ctr, Dept Radiol, D-6900 Heidelberg, Germany
[3] Univ Michigan, Dept Surg, Ann Arbor, MI 48109 USA
[4] Gen Elect Med Syst, Milwaukee, WI USA
关键词
gadolinium; MR angiography; abdominal aorta;
D O I
10.1097/00004424-200105000-00006
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
RATIONALE AND OBJECTIVES. TO optimize three-dimensional gadolinium magnetic resonance angiography (3D-Gd-MRA) of the aorta and runoff vessels by addressing fundamentally different requirements for temporal and spatial resolution in a single semiautomated examination. METHODS, The technique was designed to obtain pure arterial-phase SD-Gd-MR angiograms with adequate spatial resolution for each station while avoiding incomplete enhancement due to delayed filling vessels as well as venous overlay. During gadolinium-chelate infusion, a breath-held multiphase 3D-Gd-MRA scan was initiated in the aorta by automatic triggering, followed by automatic table movement, The acquisition was tailored to the vessels of interest by tilting of the 3D volumes, A spatial resolution of 1.7 x 13 x 0.8 mm in the calves was achieved by use of elliptical-centric k-space reordering. Signal-to-noise ratio was maximized with a 12-element peripheral vascular coil. Twelve patients with peripheral vascular disease were studied, RESULTS. In cases of aortic occlusive disease (n = 2), dissections (n = 3), or aneurysms (n = 4), substantially delayed fill-in of reconstituted arteries, false lumens, or aneurysmal segments occurred, which was detected only on the later 3D-Gd-MRA phase. High-resolution arterial-phase scans in the calves were obtained, with only one case of substantial venous overlay. Correlation to digital subtraction angiography revealed excellent agreement of pathological findings, CONCLUSIONS, Multiphase-multistep 3D-Gd-MRA reduces the limitations of standard 3D-Gd-MRA techniques with respect to anatomic coverage, spatial resolution, and nonuniform arterial vessel enhancement.
引用
收藏
页码:283 / 291
页数:9
相关论文
共 25 条
[1]   Contrast-enhanced magnetic resonance angiography of peripheral vessels - Different contrast agent applications and sequence strategies: A review [J].
Boos, M ;
Lentschig, M ;
Scheffler, K ;
Bongartz, GM ;
Steinbrich, W .
INVESTIGATIVE RADIOLOGY, 1998, 33 (09) :538-546
[2]  
Czum JM, 2000, J MAGN RESON IMAGING, V12, P769, DOI 10.1002/1522-2586(200011)12:5<769::AID-JMRI16>3.3.CO
[3]  
2-J
[4]   Gadolinium-enhanced three-dimensional MR angiography of the aorta and peripheral arteries: Evaluation of a multistation examination using two gadopentetate dimeglumine infusions [J].
Earls, JP ;
Patel, NH ;
Smith, PA ;
DeSena, S ;
Meissner, MH .
AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (03) :599-604
[5]   Peripheral vascular tree stenoses: Evaluation with moving-bed infusion-tracking MR angiography [J].
Ho, KYJAM ;
Leiner, T ;
de Haan, MW ;
Kessels, AGH ;
Kitslaar, PJEHM ;
van Engelshoven, JMA .
RADIOLOGY, 1998, 206 (03) :683-692
[6]   Peripheral vascular tree stenoses: Detection with subtracted and nonsubtracted MR angiography [J].
Ho, KYJAM ;
de Haan, MW ;
Kessels, AGH ;
Kitslaar, PJEHM ;
van Engelshoven, JMA .
RADIOLOGY, 1998, 206 (03) :673-681
[7]  
Ho VB, 1999, JMRI-J MAGN RESON IM, V10, P376, DOI 10.1002/(SICI)1522-2586(199909)10:3<376::AID-JMRI20>3.0.CO
[8]  
2-U
[9]   Carotid arteries: Maximizing arterial to venous contrast in fluoroscopically triggered contrast-enhanced MR angiography with elliptic centric view ordering [J].
Huston, J ;
Fain, SB ;
Riederer, SJ ;
Wilman, AH ;
Bernstein, MA ;
Busse, RF .
RADIOLOGY, 1999, 211 (01) :265-273
[10]  
Isoda H, 1998, AM J NEURORADIOL, V19, P1241