Comparison of simplified methods for pesticide residue analysis -: Use of large-volume injection in capillary gas chromatography

被引:27
作者
López, FJ [1 ]
Beltran, J [1 ]
Forcada, M [1 ]
Hernández, F [1 ]
机构
[1] Univ Jaume 1, Expt Sci Dept, Castellon de La Plana 12080, Spain
关键词
extraction methods; water analysis; environmental analysis; pesticides; organophosphorus compounds; large-volume injection; injection methods;
D O I
10.1016/S0021-9673(98)00393-8
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The combination of manual and automated extraction procedures using low sample volumes (5-50 ml) with large-volume oncolumn injection (LVI) (200 mu l) in capillary gas chromatography with flame photometric detection (GC-FPD) has allowed the determination of 16 organophosphorus pesticides in clean water samples at the low ng l(-1) level with an important simplification in the sample preparation step. A simple and fast offline liquid-liquid microextraction procedure (2-5 ml water/1 ml methyl tert.-butyl ether) has been applied to spiked groundwater samples (containing 0.5 ng of each pesticide) with good recoveries lover 80%) and precision (better than 10%), giving detection limits between 5 and 100 ng l(-1) using 200 mu l injections in the GC-FPD system. The application of an inline automated Liquid-Liquid microextraction-LVI-GC procedure (2 ml water/2 ml methyl tert.-butyl ether: injection of 200 mu l in GC-FPD) using the autosampler ASPEC XL led to lower recoveries (>50%) as a result of the low efficiency for mixing organic and aqueous phases, although with very satisfactory coefficients of variation (lower than 78) and detection Limits between 20 and 200 ng l(-1). Manual and automated solid-phase extraction procedures using the well known C-18 cartridges and the new Oasis HLB have been applied to groundwater samples (5-50 ml) spiked with 1 ng of each pesticide. Results obtained for both the manual and the automated procedures were satisfactory (recoveries over 80%) and the limits of detection for 50 ml sample volume ranged from 1 to 6 ng l(-1). (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:25 / 33
页数:9
相关论文
共 15 条
[1]   Determination of triazine herbicides by capillary gas chromatography with large-volume on-column injection [J].
Beltran, J ;
Lopez, FJ ;
Forcada, M ;
Hernandez, F .
CHROMATOGRAPHIA, 1997, 44 (5-6) :274-278
[2]   Microextraction procedures combined with large volume injection in capillary gas chromatography for the determination of pesticide residues in environmental aqueous samples [J].
Beltran, J ;
López, FJ ;
Forcada, M ;
Hernandez, F .
ANALYTICA CHIMICA ACTA, 1997, 356 (2-3) :125-133
[3]   SOLID-PHASE EXTRACTION OF PESTICIDE-RESIDUES FROM GROUND-WATER - COMPARISON BETWEEN EXTRACTION CARTRIDGES AND EXTRACTION DISKS [J].
BELTRAN, J ;
LOPEZ, FJ ;
HERNANDEZ, F .
ANALYTICA CHIMICA ACTA, 1993, 283 (01) :297-303
[4]  
BOUVIER ESP, 1997, LC GC EUR, V10, P577
[5]  
BRIN MF, 1995, NEUROL DIS, V30, P495
[6]   SOLID-PHASE EXTRACTION IN MULTI-RESIDUE PESTICIDE ANALYSIS OF WATER [J].
FONT, G ;
MANES, J ;
MOLTO, JC ;
PICO, Y .
JOURNAL OF CHROMATOGRAPHY, 1993, 642 (1-2) :135-161
[7]   INTRODUCTION OF WATER AND WATER-CONTAINING SOLVENT MIXTURES IN CAPILLARY GAS-CHROMATOGRAPHY .1. FAILURE TO PRODUCE WATER-WETTABLE PRECOLUMNS (RETENTION GAPS) [J].
GROB, K ;
LI, ZW .
JOURNAL OF CHROMATOGRAPHY, 1989, 473 (02) :381-390
[8]   ONLINE COUPLING OF SOLID-PHASE EXTRACTION AND GAS-CHROMATOGRAPHY WITH ATOMIC-EMISSION DETECTION FOR ANALYSIS OF TRACE POLLUTANTS IN AQUEOUS SAMPLES [J].
HANKEMEIER, T ;
LOUTER, AJH ;
RINKEMA, FD ;
BRINKMAN, UAT .
CHROMATOGRAPHIA, 1995, 40 (3-4) :119-124
[9]   GC INSTRUMENTATION FOR ON-COLUMN INJECTION OF LARGE VOLUMES - AUTOMATED OPTIMIZATION OF CONDITIONS [J].
MUNARI, F ;
COLOMBO, PA ;
MAGNI, P ;
ZILIOLI, G ;
TRESTIANU, S ;
GROB, K .
JOURNAL OF MICROCOLUMN SEPARATIONS, 1995, 7 (04) :403-409
[10]  
NOIJ THM, 1995, HRC-J HIGH RES CHROM, V18, P535, DOI 10.1002/jhrc.1240180905