Determination of highly soluble L-carnitine in biological samples by reverse phase high performance liquid chromatography with fluorescent derivatization

被引:24
作者
Cao, Qing-Ri
Ren, Shan
Park, Mi-Jin
Choi, Yun-Jaie
Lee, Beom-Jin [1 ]
机构
[1] Kangwon Natl Univ, Coll Pharm, Natl Res Lab Bioavailabil Control, Chunchon, South Korea
[2] Seoul Natl Univ, Coll Agr & Life Sci, Seoul 151742, South Korea
关键词
L-carnitine; in vivo biological samples; HPLC analysis; fluorescence derivatization; cows;
D O I
10.1007/BF02993974
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
This study was performed in order to validate an effective high performance liquid chromatograpy (HPLC) method to determine L-carnitine in biological samples such as plasma, milk and muscle in cows. An L-carnitine derivative for fluorescence absorption was synthesized with 1-aminoanthracene (16 mg/mL in acetone) and 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide hydrochloride (EDAC; 160 mg/mL in 0.01 M NaH2PO4 buffer) as a precolumn fluorescent derivative reagent. gamma-Butyrobetaine HCl was used as an internal standard. A reversed-phase column with fluorescence detection at the excitation and emission wavelengths of 248 and 418 nm were used. The mobile phase consisted of 30% acetonitrile with 0.1 M ammonium acetate in water (pH 3.5) adjusted with acetic acid and delivered at a flow rate of 1.5 mL/min. The L-carnitine concentration in plasma, milk and muscle samples of cows after oral feeding with 24 g L-carnitine/day for 2 months was then determined. All biological samples were deproteinated by barium hydroxide and zinc sulfate heptahydrate before the derivative reaction. Blank cow plasma was dialyzed using cellulose membrane for standard calibration. The calibration curve showed good linearity (r(2)>0.999) over the concentration range of 50 to 5000 ng/mL. The precision and accuracy were also satisfactory with less than 15% intra- and inter-day coefficiency of variations. The peaks of L-carnitine and internal standard in HPLC chromatography were successfully separated in plasma, milk and muscle samples of cows. The current derivatization method of L-carnitine for fluorescence detection was simple and adequately sensitive and could be applied to determine L-carnitine in biological samples.
引用
收藏
页码:1041 / 1046
页数:6
相关论文
共 14 条
[1]   PHARMACOKINETIC CONSIDERATIONS FOR THE THERAPEUTIC USE OF CARNITINE IN HEMODIALYSIS-PATIENTS [J].
BRASS, EP .
CLINICAL THERAPEUTICS, 1995, 17 (02) :176-185
[2]   CARNITINE - METABOLISM AND FUNCTIONS [J].
BREMER, J .
PHYSIOLOGICAL REVIEWS, 1983, 63 (04) :1420-1480
[3]   MUSCLE CARNITINE DEFICIENCY AND LIPID STORAGE MYOPATHY IN PATIENTS WITH MITOCHONDRIAL MYOPATHY [J].
CAMPOS, Y ;
HUERTAS, R ;
BAUTISTA, J ;
GUTIERREZ, E ;
APARICIO, M ;
LORENZO, G ;
SEGURA, D ;
VILLANUEVA, M ;
CABELLO, A ;
ALESSO, L ;
ARENAS, J .
MUSCLE & NERVE, 1993, 16 (07) :778-781
[4]  
DIDONATO S, 1994, MYOLOGY, P1587
[5]   DETERMINATION OF CARNITINE AND SATURATED-ACYL GROUP CARNITINES IN HUMAN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH FLUORESCENCE DETECTION [J].
KAMIMORI, H ;
HAMASHIMA, Y ;
KONISHI, M .
ANALYTICAL BIOCHEMISTRY, 1994, 218 (02) :417-424
[6]  
Kuroda N, 1996, CHEM PHARM BULL, V44, P1525
[7]   Determination of L-carnitine, acetyl-L-carnitine and propionyl-L-carnitine in human plasma by high-performance liquid chromatography after pre-column derivatization with 1-aminoanthracene [J].
Longo, A ;
Bruno, G ;
Curti, S ;
Mancinelli, A ;
Miotto, G .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 686 (02) :129-139
[8]   L-carnitine moiety assay: an up-to-date reappraisal covering the commonest methods for various applications [J].
Marzo, A ;
Curti, S .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1997, 702 (1-2) :1-20
[9]   QUANTIFICATION OF CARNITINE AND SPECIFIC ACYLCARNITINES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY - APPLICATION TO NORMAL HUMAN URINE AND URINE FROM PATIENTS WITH METHYLMALONIC ACIDURIA, ISOVALERIC ACIDEMIA OR MEDIUM-CHAIN ACYL-COA DEHYDROGENASE-DEFICIENCY [J].
MINKLER, PE ;
HOPPEL, CL .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1993, 613 (02) :203-221
[10]   A RAPID QUANTITATIVE-DETERMINATION OF ACETAMINOPHEN IN PLASMA [J].
OCONNELL, SE ;
ZURZOLA, FJ .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1982, 71 (11) :1291-1294