Desiccant wheel regenerated by thermal energy from a microcogenerator: Experimental assessment of the performances

被引:69
作者
Angrisani, Giovanni [2 ]
Capozzoli, Alfonso [3 ]
Minichiello, Francesco [1 ]
Roselli, Carlo [2 ]
Sasso, Maurizio [2 ]
机构
[1] Univ Naples Federico II, DETEC, I-80125 Naples, Italy
[2] Univ Sannio, DING, I-82100 Benevento, Italy
[3] Politecn Torino, DENER, TEBE Res Grp, I-10129 Turin, Italy
关键词
Desiccant wheel; HVAC system; MCHP; Experimental analysis; Latent loads; Regeneration temperature; SILICA-GEL; DEHUMIDIFICATION; SYSTEMS;
D O I
10.1016/j.apenergy.2010.09.025
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Hybrid desiccant HVAC systems have shown several advantages, compared to conventional cooling and dehumidification systems. Therefore, their use is also spreading for tertiary and residential buildings, especially when the regeneration of the desiccant can be obtained by using available waste heat. In this paper, an experimental analysis is presented on the performances of a silica-gel desiccant wheel, inserted in a test facility characterized by an advanced desiccant air handling unit, coupled to an electric chiller, a natural gas-fired boiler and a small scale cogenerator. The desiccant wheel is regenerated by using low temperature thermal energy recovered from the microcogenerator. The effects of the main thermal-hygrometric parameters (outdoor air humidity ratio and temperature, regeneration air temperature) on the desiccant wheel performances have been experimentally evaluated; in particular, the thermal-hygrometric properties of the process air exiting the rotor and the desiccant wheel effectiveness values have been obtained. Finally, fixing the regeneration temperature at its maximum available value (65 degrees C), ventilation and internal latent loads that the desiccant wheel can handle have been evaluated and compared to the required values, both for a set of cities all over the world and as a function of the thermal-hygrometric outdoor conditions. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1354 / 1365
页数:12
相关论文
共 33 条
[1]   Evaluation and optimization of solar desiccant wheel performance [J].
Ahmed, MH ;
Kattab, NM ;
Fouad, M .
RENEWABLE ENERGY, 2005, 30 (03) :305-325
[2]  
ANGRISANI G, 2009, P ECOS 2009 22 INT C
[3]  
[Anonymous], 2009, ASHRAE HDB FUND
[4]  
ASHRAE, 2009, ASHRAE HDB FUND
[5]  
ASHRAE, 2008, ASHRAE HDB HVAC SYST
[6]   Update on desiccant wheel model [J].
Beccali, M ;
Adhikari, RS ;
Butera, F ;
Franzitta, V .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2004, 28 (12) :1043-1049
[7]   Simplified models for the performance evaluation of desiccant wheel dehumidification [J].
Beccali, M ;
Butera, F ;
Guanella, R ;
Adhikari, RS .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2003, 27 (01) :17-29
[8]   Hybrid HVAC systems with chemical dehumidification for supermarket applications [J].
Capozzoli, A ;
Mazzei, P ;
Minichiello, F ;
Palma, D .
APPLIED THERMAL ENGINEERING, 2006, 26 (8-9) :795-805
[9]   Experiences with a gas driven, desiccant assisted air conditioning system with geothermal energy for an office building [J].
Casas, W ;
Schmitz, G .
ENERGY AND BUILDINGS, 2005, 37 (05) :493-501
[10]   Desiccant cooling air conditioning: a review [J].
Daou, K ;
Wang, RZ ;
Xia, ZZ .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2006, 10 (02) :55-77