Two-dimensional ultrasound receive army using an angle-tuned Fabry-Perot polymer film sensor for transducer field characterization and transmission ultrasound imaging

被引:32
作者
Beard, PC [1 ]
机构
[1] UCL, Dept Med Phys & Bioengn, London WC1E 6BT, England
基金
英国工程与自然科学研究理事会;
关键词
D O I
10.1109/TUFFC.2005.1504022
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A 2-D optical ultrasound receive array has been investigated. The transduction mechanism is based upon the detection of acoustically induced changes in the optical thickness of a thin polymer film acting as a Fabry-Perot sensing interferometer (FPI). By illuminating the sensor with a large-area laser beam and mechanically scanning a photodiode across the reflected output beam, while using a novel angle-tuned phase bias control system to optimally set the FPI working point, a notional 2-D ultrasound array was synthesized. To demonstrate the concept, 1-D and 2-D ultrasound field distributions produced by planar 3.5-MHz and focused 5-MHz PZT ultrasound transducers were mapped. The system was also evaluated by performing transmission ultrasound imaging of a spatially calibrated target. The "array" aperture, defined by the dimensions of the incident optical field, was elliptical, of dimensions 16 X 12 mm and spatially sampled in steps of 0.1 mm or 0.2 mm. Element sizes, defined by the photodiode aperture, of 0.8, 0.4, and 0.2 mm were variously used for these experiments. Two types of sensor were evaluated. One was a discrete 75-mu m-thick polyethylene terephthalate FPI bonded to a polymer backing stub which had a wideband peak noise-equivalent pressure of 6.5 kPa and an acoustic bandwidth 12 MHz. The other was a 40-mu m Parylene film FPI which was directly vacuum-deposited onto a glass backing stub and had an NEP of 8 kPa and an acoustic bandwidth of 17.5 MHz. It is considered that this approach offers an alternative to piezoelectric ultrasound arrays for transducer field characterization, transmission medical and industrial ultrasound imaging, biomedical photoacoustic imaging, and ultrasonic nondestructive testing.
引用
收藏
页码:1002 / 1012
页数:11
相关论文
共 18 条
[1]   Interrogation of free-space Fabry-Perot sensing interferometers by angle tuning [J].
Beard, PC .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2003, 14 (11) :1998-2005
[2]  
Beard PC, 2000, ULTRASON, P1183, DOI 10.1109/ULTSYM.2000.921534
[3]   Characterization of a polymer film optical fiber hydrophone for use in the range 1 to 20 MHz: A comparison with PVDF needle and membrane hydrophones [J].
Beard, PC ;
Hurrell, AM ;
Mills, TN .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (01) :256-264
[4]   Transduction mechanisms of the Fabry-Perot polymer film sensing concept for wideband ultrasound detection [J].
Beard, PC ;
Pérennès, F ;
Mills, TN .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (06) :1575-1582
[5]   Optical fiber photoacoustic-photothermal probe [J].
Beard, PC ;
Perennes, F ;
Draguioti, E ;
Mills, TN .
OPTICS LETTERS, 1998, 23 (15) :1235-1237
[6]  
BEARD PC, 2002, P SOC PHOTO-OPT INS, V1618, P54
[7]  
COX BT, 2004, J PHYS C SER ADV MET, P32
[8]   High frequency ultrasound imaging with optical arrays [J].
Hamilton, JD ;
O'Donnell, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1998, 45 (01) :216-235
[9]   High frequency optoacoustic arrays using etalon detection [J].
Hamilton, JD ;
Buma, T ;
Spisar, M ;
O'Donnell, M .
IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2000, 47 (01) :160-169
[10]  
HOLDEN J, 1949, P PHYS SOC B, V62, P105