Implementation and evaluation of the SPRINT protocol for tight glycaemic control in critically ill patients: a clinical practice change

被引:156
作者
Chase, J. Geoffrey [1 ]
Shaw, Geoffrey [2 ]
Le Compte, Aaron [1 ]
Lonergan, Timothy [1 ]
Willacy, Michael [1 ]
Wong, Xing-Wei [1 ]
Lin, Jessica [1 ]
Lotz, Thomas [1 ]
Lee, Dominic [3 ]
Hann, Christopher [1 ]
机构
[1] Univ Canterbury, Dept Mech Engn, Christchurch 8140, New Zealand
[2] Univ Otago, Christchurch Hosp, Christchurch Sch Med & Hlth Sci, Dept Intens Care, Christchurch 8140, New Zealand
[3] Univ Canterbury, Dept Math & Stat, Christchurch 8140, New Zealand
来源
CRITICAL CARE | 2008年 / 12卷 / 02期
关键词
D O I
10.1186/cc6868
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Introduction Stress-induced hyperglycaemia is prevalent in critical care. Control of blood glucose levels to within a 4.4 to 6.1 mmol/L range or below 7.75 mmol/L can reduce mortality and improve clinical outcomes. The Specialised Relative Insulin Nutrition Tables (SPRINT) protocol is a simple wheel-based system that modulates insulin and nutritional inputs for tight glycaemic control. Methods SPRINT was implemented as a clinical practice change in a general intensive care unit (ICU). The objective of this study was to measure the effect of the SPRINT protocol on glycaemic control and mortality compared with previous ICU control methods. Glycaemic control and mortality outcomes for 371 SPRINT patients with a median Acute Physiology And Chronic Health Evaluation (APACHE) II score of 18 (interquartile range [IQR] 15 to 24) are compared with a 413-patient retrospective cohort with a median APACHE II score of 18 (IQR 15 to 23). Results Overall, 53.9% of all measurements were in the 4.4 to 6.1 mmol/L band. Blood glucose concentrations were found to be log-normal and thus log-normal statistics are used throughout to describe the data. The average log-normal glycaemia was 6.0 mmol/L (standard deviation 1.5 mmol/L). Only 9.0% of all measurements were below 4.4 mmol/L, with 3.8% below 4 mmol/L and 0.1% of measurements below 2.2 mmol/L. On SPRINT, 80% more measurements were in the 4.4 to 6.1 mmol/L band and standard deviation of blood glucose was 38% lower compared with the retrospective control. The range and peak of blood glucose were not correlated with mortality for SPRINT patients (P > 0.30). For ICU length of stay (LoS) of greater than or equal to 3 days, hospital mortality was reduced from 34.1% to 25.4% (-26%) (P = 0.05). For ICU LoS of greater than or equal to 4 days, hospital mortality was reduced from 34.3% to 23.5% (-32%) (P = 0.02). For ICU LoS of greater than or equal to 5 days, hospital mortality was reduced from 31.9% to 20.6% (-35%) (P = 0.02). ICU mortality was also reduced but the P value was less than 0.13 for ICU LoS of greater than or equal to 4 and 5 days. Conclusion SPRINT achieved a high level of glycaemic control on a severely ill critical cohort population. Reductions in mortality were observed compared with a retrospective hyperglycaemic cohort. Range and peak blood glucose metrics were no longer correlated with mortality outcome under SPRINT.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Effect of low-calorie parenteral nutrition on the incidence and severity of hyperglycemia in surgical patients: A randomized, controlled trial
    Ahrens, CL
    Barletta, JF
    Kanji, S
    Tyburski, JG
    Wilson, RF
    Janisse, JJ
    Devlin, JW
    [J]. CRITICAL CARE MEDICINE, 2005, 33 (11) : 2507 - 2512
  • [2] Hyperglycemia and infection: Which is the chicken and which is the egg?
    Bistrian, BR
    [J]. JOURNAL OF PARENTERAL AND ENTERAL NUTRITION, 2001, 25 (04) : 180 - 181
  • [3] Bland DK, 2005, AM J CRIT CARE, V14, P370
  • [4] Stress hyperglycaemia and increased risk of death after myocardial infarction in patients with and without diabetes: a systematic overview
    Capes, SE
    Hunt, D
    Malmberg, K
    Gerstein, HC
    [J]. LANCET, 2000, 355 (9206) : 773 - 778
  • [5] Applied nutrition in ICU patients - A consensus statement of the American College of Chest Physicians
    Cerra, FB
    Benitez, MR
    Blackburn, GL
    Irwin, RS
    Jeejeebhoy, K
    Katz, DP
    Pingleton, SK
    Pomposelli, J
    Rombeau, JL
    Shronts, E
    Wolfe, RR
    Zaloga, GP
    [J]. CHEST, 1997, 111 (03) : 769 - 778
  • [6] Model-based glycaemic control in critical care-A review of the state of the possible
    Chase, J. G.
    Shaw, G. M.
    Wong, X. W.
    Lotz, T.
    Lin, J.
    Hann, C. E.
    [J]. BIOMEDICAL SIGNAL PROCESSING AND CONTROL, 2006, 1 (01) : 3 - 21
  • [7] Chase J Geoffrey, 2005, Diabetes Technol Ther, V7, P274, DOI 10.1089/dia.2005.7.274
  • [8] Adaptive bolus-based targeted glucose regulation of hyperglycaemia in critical care
    Chase, JG
    Shaw, GM
    Lin, J
    Doran, CV
    Hann, C
    Robertson, MB
    Browne, PM
    Lotz, T
    Wake, GC
    Broughton, B
    [J]. MEDICAL ENGINEERING & PHYSICS, 2005, 27 (01) : 1 - 11
  • [9] CHASE JG, 2004, INT J INTELL SYST, V1, P79
  • [10] Expert PID control system for blood glucose control in critically Ill patients
    Chee, F
    Fernando, TL
    Savkin, AV
    van Heeden, V
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2003, 7 (04): : 419 - 425