Comparative study of a solid-phase extraction system coupled to capillary electrophoresis in the determination of haloacetic compounds in tap water

被引:49
作者
Martínez, D [1 ]
Borrull, F [1 ]
Calull, M [1 ]
机构
[1] Univ Rovira & Virgili, Dept Quim Analit & Quim Organ, Tarragona 43005, Spain
关键词
solid-phase extraction; extraction methods; water analysis; organochlorine compounds; haloacetic acids;
D O I
10.1016/S0021-9673(98)00752-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This study compares four different commercial sorbents, LC-SAX (a quaternary ammonium anion exchanger), LiChrolut EN (a highly crosslinked styrene-divinylbenzene), Envi-Carb (a graphitized carbon black) and Oasis HLB [a macroporous poly(divinylbenzene-co-N-vinylpyrrolidone) copolymer], for the solid-phase extraction (SPE) of,various haloacetic compounds from aqueous samples. The recoveries with the different sorbents were studied by coupling an off-line SPE system to capillary electrophoresis with indirect photometric detection. The recoveries were highest when LiChrolut EN was used. The limits of detection for the compounds are in the low microgram per litre range and the recovery values are over 80% for dichloroacetic acid and trichloroacetic acid, two of the most habitual haloacetic acids in chlorinated water, when 500 ml of standard solution was preconcentrated using this sorbent. Finally, the performance of the method with different water samples, the effect of chlorination in a treatment plant and the evolution of the haloacetic acids in the water distribution system were tested and the results were compared with those obtained using liquid-liquid extraction and gas chromatography-mass spectrometry. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:105 / 112
页数:8
相关论文
共 26 条
[1]  
[Anonymous], 1995, STANDARD METHODS EXA
[2]  
Arora H, 1997, J AM WATER WORKS ASS, V89, P60
[3]  
BARTH RC, 1992, J AM WATER WORKS ASS, V84, P94
[4]   A REVIEW OF SOLID-PHASE EXTRACTION - BASIC PRINCIPLES AND NEW DEVELOPMENTS [J].
BERRUETA, LA ;
GALLO, B ;
VICENTE, F .
CHROMATOGRAPHIA, 1995, 40 (7-8) :474-483
[5]  
Bouvier ESP, 1995, LC GC-MAG SEP SCI, V13, P120
[6]   EVALUATION OF CARRIER ELECTROLYTES FOR CAPILLARY ZONE ELECTROPHORESIS OF LOW-MOLECULAR-MASS ANIONS WITH INDIRECT UV DETECTION [J].
COUSINS, SM ;
HADDAD, PR ;
BUCHBERGER, W .
JOURNAL OF CHROMATOGRAPHY A, 1994, 671 (1-2) :397-402
[7]  
GREINER AD, 1992, J AM WATER WORKS ASS, V84, P99
[8]   A one-year survey of halogenated disinfection by-products in the distribution system of treatment plants using three different disinfection processes [J].
LeBel, GL ;
Benoit, FM ;
Williams, DT .
CHEMOSPHERE, 1997, 34 (11) :2301-2317
[9]   Strategy for the screening of organic pollutants in a river basin - An overview of the Nitra river monitoring programme [J].
Liska, I ;
Barcelo, D ;
Grasserbauer, M .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1996, 15 (08) :326-334
[10]   Capillary zone electrophoresis with indirect UV detection of haloacetic acids in water [J].
Martínez, D ;
Farré, J ;
Borrull, F ;
Calull, M ;
Ruana, J ;
Colom, A .
JOURNAL OF CHROMATOGRAPHY A, 1998, 808 (1-2) :229-236