Digital wireless radiology consultations with a portable computer

被引:18
作者
Reponen, J [1 ]
Ilkko, E [1 ]
Jyrkinen, L [1 ]
Karhula, V [1 ]
Tervonen, O [1 ]
Laitinen, J [1 ]
Leisti, EL [1 ]
Koivula, A [1 ]
Suramo, KI [1 ]
机构
[1] Univ Hosp Oulu, Dept Diagnost Radiol, Oulu, Finland
关键词
D O I
10.1258/1357633981932244
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
摘要
A wireless system for radiological subspecialist consultation based on a portable personal computer and a CSM cellular phone was tested. A link with secure access to the hospital image network was built. A total of 68 emergency computerized tomography (CT) examinations were transmitted. Transmission time via CSM for a single CT image was 1 min and for a complete head scan was 18 min. The transmitted images were acceptable for final diagnosis in 72% of the cases, the rest being acceptable for preliminary diagnosis. The diagnosis from the transmitted images did not change after a later review of the original images in 97% of cases. The wireless link saved a hospital visit by the senior radiologist in 24% of cases. The results show that a remote consultation link can be built with readily available technology and that the technique is useful in radiological subspecialist consultations for CT images.
引用
收藏
页码:201 / 205
页数:5
相关论文
共 15 条
  • [1] TELERADIOLOGY - AN ASSESSMENT
    BATNITZKY, S
    ROSENTHAL, SJ
    SIEGEL, EL
    WETZEL, LH
    MURPHEY, MD
    COX, GG
    MCMILLAN, JH
    TEMPLETON, AW
    DWYER, SJ
    [J]. RADIOLOGY, 1990, 177 (01) : 11 - 17
  • [2] TELERADIOLOGY - COSTS OF HARDWARE AND COMMUNICATIONS
    DWYER, SJ
    TEMPLETON, AW
    BATNITZKY, S
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1991, 156 (06) : 1279 - 1282
  • [3] CLINICAL-EVALUATION OF IRREVERSIBLE IMAGE COMPRESSION - ANALYSIS OF CHEST IMAGING WITH COMPUTED RADIOGRAPHY
    ISHIGAKI, T
    SAKUMA, S
    IKEDA, M
    ITOH, Y
    SUZUKI, M
    IWAI, S
    [J]. RADIOLOGY, 1990, 175 (03) : 739 - 743
  • [4] JUTRAS A, 1959, AMER J ROENTGENOL RA, V82, P1099
  • [5] JPEG COMPRESSION FOR PACS
    KAJIWARA, K
    [J]. COMPUTER METHODS AND PROGRAMS IN BIOMEDICINE, 1992, 37 (04) : 343 - 351
  • [6] EFFECT OF A NEW COMPUTED TOMOGRAPHIC IMAGE TRANSFER SYSTEM ON MANAGEMENT OF REFERRALS TO A REGIONAL NEUROSURGICAL SERVICE
    LEE, T
    LATHAM, J
    KERR, RSC
    KAAR, G
    TEDDY, PJ
    DOBSON, D
    ANSLOW, P
    [J]. LANCET, 1990, 336 (8707) : 101 - 103
  • [7] COMPRESSION OF RADIOLOGICAL IMAGES WITH 512, 1,024, AND 2,048 MATRICES
    LO, SC
    HUANG, HK
    [J]. RADIOLOGY, 1986, 161 (02) : 519 - 525
  • [8] DATA-COMPRESSION - EFFECT ON DIAGNOSTIC-ACCURACY IN DIGITAL CHEST RADIOGRAPHY
    MACMAHON, H
    DOI, K
    SANADA, S
    MONTNER, SM
    GIGER, ML
    METZ, CE
    NAKAMORI, N
    YIN, FF
    XU, XW
    YONEKAWA, H
    TAKEUCHI, H
    [J]. RADIOLOGY, 1991, 178 (01) : 175 - 179
  • [9] MURPHY RLH, 1970, AM REV RESPIR DIS, V102, P771
  • [10] LOW-COST DIGITAL TELERADIOLOGY
    REPONEN, J
    LAHDE, S
    TERVONEN, O
    ILKKO, E
    RISSANEN, T
    SURAMO, I
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 1995, 19 (03) : 226 - 231