On the transformation behaviour, mechanical properties and biocompatibility of two NiTi-based shape memory alloys: NiTi42 and NiTi42Cu7

被引:60
作者
Es-Souni, M
Es-Souni, M
Brandies, HF
机构
[1] Univ Appl Sci, Fachhsch Kiel, D-24149 Kiel, Germany
[2] Univ Kiel, Clin Orthodont, D-24113 Kiel, Germany
关键词
shape memory alloys; NiTi; NiTiCu; bending properties; biocompatibility; cytotoxicity;
D O I
10.1016/S0142-9612(00)00406-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The transformation behaviour, mechanical properties and cytotoxicity of a binary NiTi42 and a ternary NiTi42Cu7 alloy have been investigated. The transformation temperatures were determined via differential scanning calorimetry, the mechanical properties have been investigated in 3-point bending tests in the temperature range between 6 and 60 degreesC. The cytotoxicity tests were performed on both alloys in cultured epithelial cells from human gingiva. The cytotoxicity investigations included both MTT tests and morphological observations. It is shown that although the ternary alloy is characterised by a narrower hysteresis and superior mechanical properties, including fatigue resistance, its cytotoxicity is higher than that of the binary alloy. This is thought to arise from the release of copper ions in the medium, which upon atomic absorption spectroscopy measurements amount to approximately 2.8 mug cm(-2) for an incubation period of 7 days. (C) 2001 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:2153 / 2161
页数:9
相关论文
共 21 条
[1]  
BOURNE JA, 1997, HDB IMMUNOPEROXYDASE, P16
[2]  
DUERIG TW, 1995, MATER RES SOC SYMP P, V360, P497
[3]  
DUERIG TW, 1995, MAT SMART SYSTEMS, P159
[4]  
Gil FJ, 1999, J BIOMED MATER RES, V48, P682, DOI 10.1002/(SICI)1097-4636(1999)48:5<682::AID-JBM12>3.0.CO
[5]  
2-M
[6]   Relevant aspects in the clinical applications of NiTi shape memory alloys [J].
Gil, FX ;
Manero, JM ;
Planell, JA .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1996, 7 (07) :403-406
[7]   Biocompatible and mechanical properties of low temperature deposited quaternary (Ti,Al,V)N coatings on Ti6Al4V titanium alloy substrates [J].
Grant, DM ;
Lo, WJ ;
Parker, KG ;
Parker, TL .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1996, 7 (09) :579-584
[8]  
JUDD DA, 1997, FOCUS, V19, P2
[9]  
Melton KN., 1998, SHAPE MEMORY MAT, P220
[10]   Stress-induced martensitic transformation of a NiTi alloy in isothermal shear, tension and compression [J].
Orgeas, L ;
Favier, D .
ACTA MATERIALIA, 1998, 46 (15) :5579-5591