Accuracy of User-Friendly Blood Typing Kits Tested Under Simulated Military Field Conditions

被引:11
作者
Bienek, Diane R. [1 ]
Charlton, David G. [1 ]
机构
[1] USN, Med Res Unit San Antonio Gen Dynam Informat Techn, San Antonio, TX 78235 USA
关键词
IDENTIFICATION CARDS; DENTAL EQUIPMENT; ENVIRONMENT; STABILITY;
D O I
10.7205/MILMED-D-10-00339
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Rapid user-friendly ABO Rh blood typing kits (Eldon Home Kit 2511, ABO Rh Combination Blood Typing Experiment Kit) were evaluated to determine their accuracy when used under simulated military field conditions and after long-term storage at various temperatures and humidities. Rates of positive tests between control groups, experimental groups, and industry standards were measured and analyzed using the Fisher's exact chi-square method to identify significant differences (p <= 0.05). When Eldon Home Kits 2511 were used in various operational conditions, the results were comparable to those obtained with the control group and with the industry standard. The performance of the ABO Rh Combination Blood Typing Experiment Kit was adversely affected by prolonged storage in temperatures above 37 degrees C. The diagnostic performance of commercial blood typing kits varies according to product and environmental storage conditions.
引用
收藏
页码:454 / 460
页数:7
相关论文
共 21 条
[1]  
*AM ASS BLOOD BANK, 2008, STAND BLOOD BANKS TR
[2]  
*AS PAC CONN, 2010, LIV KOR CLIM WEATH
[3]  
Bamberg Richard, 2005, Clin Lab Sci, V18, P203
[4]   Rapid point-of-care test to detect broad ranges of protective antigen-specific immunoglobulin G concentrations in recipients of the US-licensed anthrax vaccine [J].
Bienek, Diane R. ;
Biagini, Raymond E. ;
Charlton, David G. ;
Smith, Jerome P. ;
Sammons, Deborah L. ;
Robertson, Shirley A. .
CLINICAL AND VACCINE IMMUNOLOGY, 2008, 15 (04) :644-649
[5]   Stability of User-Friendly Blood Typing Kits Stored Under Typical Military Field Conditions [J].
Bienek, Diane R. ;
Chang, Cheow K. ;
Charlton, David G. .
MILITARY MEDICINE, 2009, 174 (10) :1075-1080
[6]  
Bolan CD, 1995, ANESTHESIA PERIOPERA, P341
[7]   Clinical user evaluation of field dental equipment under military deployment conditions [J].
Charlton, David G. ;
Ehrlich, A. Dale ;
Miniotis, Nicholas J. .
MILITARY MEDICINE, 2008, 173 (01) :54-62
[8]   Evaluation of field dental equipment in a deployment environment [J].
Charlton, DG ;
Ehrlich, AD ;
Ragain, JC ;
Lyles, MB ;
Roberts, HW .
MILITARY MEDICINE, 2006, 171 (03) :261-267
[9]  
ENSIGN BG, 1995, MIL MED, V160, P288
[10]   Changes in properties of nonaqueous elastomeric impression materials after storage of components [J].
Hondrum, SO .
JOURNAL OF PROSTHETIC DENTISTRY, 2001, 85 (01) :73-81