The intelligent knee sleeve: A wearable biofeedback device

被引:90
作者
Munro, Bridget J. [1 ]
Campbell, Toni E. [2 ]
Wallace, Gordon G. [2 ]
Steele, Julie R. [1 ]
机构
[1] Univ Wollongong, Biomech Res Lab, Sch Hlth Sci, Wollongong, NSW 2522, Australia
[2] Univ Wollongong, ARC Ctr Excellence Electromat Sci, Intelligent Polymer Res Inst, Wollongong, NSW, Australia
基金
澳大利亚研究理事会;
关键词
ACL; fabric sensor; biofeedback; injury prevention;
D O I
10.1016/j.snb.2007.12.041
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A unique textile-based device, the intelligent knee sleeve (IKS), uses conducting polymer technology to provide feedback on knee flexion angle for injury prevention programs. After identifying the most appropriate base fabric for the sensor, 12 athletes (age = 26.1 +/- 3.2 years) performed four landing movements while wearing the sleeve, which was set to provide audible feedback at 25 degrees and 45 degrees knee flexion. Sensor and audible output (1000 Hz), knee kinematics (200 Hz) and ground reaction forces (1000 Hz) were recorded during the landing movements using an OPTOTRAK (R) motion analysis system. Paired t-tests and intraclass correlation coefficients were used to determine validity and reliability of the feedback. The results revealed that the audible feedback tone was able to significantly differentiate between different goniometer-programmed knee angles (25 degrees and 45 degrees). Knee angles computed using the kinematic data from each trial for each movement were also highly reliable (intraclass correlation coefficients, R-1 =0.903-0.988). It was concluded that although the IKS provides valid and reliable feedback on knee flexion angle, consistent feedback is dependent upon use of a sensor unaffected by environmental conditions. Such wearable biofeedback systems have application in a broad spectrum of activities, including performance enhancement, injury prevention and rehabilitation. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:541 / 547
页数:7
相关论文
共 22 条
[1]  
Caraffa A, 1996, Knee Surg Sports Traumatol Arthrosc, V4, P19, DOI 10.1007/BF01565992
[2]  
COCHRANE J, 2001, ANAL ANTERIOR CRUCIA
[3]   Effect of verbal instructions on muscle activity and risk of injury to the anterior cruciate ligament during landing [J].
Cowling, EJ ;
Steele, JR ;
McNair, PJ .
BRITISH JOURNAL OF SPORTS MEDICINE, 2003, 37 (02) :126-130
[4]   Dressware: wearable hardware [J].
De Rossi, D ;
Della Santa, A ;
Mazzoldi, A .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 1999, 7 (01) :31-35
[5]   AN INVITRO STUDY OF ANTERIOR CRUCIATE LIGAMENT STRAIN INDUCED BY QUADRICEPS AND HAMSTRINGS FORCES [J].
DRAGANICH, LF ;
VAHEY, JW .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1990, 8 (01) :57-63
[6]  
ENWEMEKA CS, 1986, SCAND J REHABIL MED, V18, P47
[7]   Force transduction materials for human-technology interfaces [J].
Fletcher, R .
IBM SYSTEMS JOURNAL, 1996, 35 (3-4) :630-638
[8]   The effect of neuromuscular training on the incidence of knee injury in female athletes - A prospective study [J].
Hewett, TE ;
Lindenfeld, TN ;
Riccobene, JV ;
Noyes, FR .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1999, 27 (06) :699-706
[9]   Plyometric training in female athletes - Decreased impact forces and increased hamstring torques [J].
Hewett, TE ;
Stroupe, AL ;
Nance, TA ;
Noyes, FR .
AMERICAN JOURNAL OF SPORTS MEDICINE, 1996, 24 (06) :765-773
[10]  
KUHN HH, 1989, ELECT CONDUCTIVE TEX