Calibration of soil heat flux sensors

被引:44
作者
van Loon, WKP
Bastings, HMH
Moors, EJ
机构
[1] Agr Univ Wageningen, Dept Environm Agr & Syst Engn, NL-6703 HD Wageningen, Netherlands
[2] DLO, Winand Staring Ctr, NL-6700 AC Wageningen, Netherlands
关键词
heat flux; soil; sensors; thermal conductivity; calibration; measuring errors;
D O I
10.1016/S0168-1923(98)00090-2
中图分类号
S3 [农学(农艺学)];
学科分类号
0901 ;
摘要
Soil heat flux is difficult to measure accurately and soil heat flux plates are difficult to calibrate. In this research the reference heat flux was calculated from the temperature gradient and independent thermal conductivity measurements. Reference conductivities, as measured by the non-steady state probe method, have an error of about 2%, while the temperature gradient was measured to an accuracy better than 1%. This results in very reliable reference measurements. Compared with this reference, commercially available heat flux plates have significant inaccuracies. The 1 mm thin TNO PU 43 T sensor was the most accurate with an average relative error of only 4%. A promising new technique is the in situ self calibration, as performed by the Huksefluks HFP-01-SC disc sensor. With self calibration this sensor achieves an accuracy of 5% and confers several advantages for field use. The MIDDLETON CN3 and TNO WS 31S sensors had relative errors of about 20%. The ring shaped sensor Huksefluks SH1 gave relatively poor results, because it measured, in fact, the temperature gradient instead of the heat flux. The results of this sensor remained poor after correcting for the thermal conductivity of the sand. For all sensors the same conclusions hold for non-steady state conditions with evaporation. The often used Philip (1961) correction factor is shown to be not very accurate: in only half of our experiments its use decreased the relative measuring error; and in some cases it made it worse. However, the correction remains useful as a tool for designing soil heat flux sensors; also a positive relation exists between the magnitude of the correction and the inaccuracy of the measurement. (C) 1998 Published by Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 16 条
[1]  
BASTINGS HMH, 1997, THESIS WAGENINGEN AG
[2]   APPARATUS FOR CALIBRATING SOIL HEAT-FLUX PLATES [J].
BISCOE, PV ;
SAFFELL, RA ;
SMITH, PD .
AGRICULTURAL METEOROLOGY, 1977, 18 (01) :49-54
[3]  
Buchan G. D., 1991, Soil analysis: physical methods., P551
[4]  
DEVRIES DA, 1952, MED LANDBOUWHOGESCHO, V52
[5]   On the sensitivity of soil-vegetation-atmosphere transfer (SVAT) schemes: Equifinality and the problem of robust calibration [J].
Franks, SW ;
Beven, KJ ;
Quinn, PF ;
Wright, IR .
AGRICULTURAL AND FOREST METEOROLOGY, 1997, 86 (1-2) :63-75
[6]  
KIRKHAM D, 1972, ADV SOIL PHYSICS
[7]   A METHOD OF MEASURING SOIL-MOISTURE BY TIME-DOMAIN REFLECTOMETRY [J].
LEDIEU, J ;
DERIDDER, P ;
DECLERCK, P ;
DAUTREBANDE, S .
JOURNAL OF HYDROLOGY, 1986, 88 (3-4) :319-328
[8]   THEORY OF HEAT FLUX METERS [J].
PHILIP, JR .
JOURNAL OF GEOPHYSICAL RESEARCH, 1961, 66 (02) :571-+
[9]  
Sheehy J. E, 1983, PRINCIPLES MEASUREME
[10]  
VANDENBOS CJ, 1997, UNPUB MEASUREMENT