Electrophysiological parameters and anatomical evaluation of left bundle branch pacing in an in vivo canine model

被引:33
作者
Chen, Xueying [1 ,2 ]
Jin, Qinchun [1 ,2 ]
Li, Bingyu [2 ,3 ,4 ]
Jia, Jianguo [2 ,3 ,4 ]
Sharma, Parikshit S. [5 ]
Huang, Weijian [6 ]
Su, Yangang [1 ,2 ]
Ge, Junbo [1 ,2 ]
机构
[1] Fudan Univ, Zhongshan Hosp, Dept Cardiol, 180 Fenglin Rd, Shanghai 200032, Peoples R China
[2] Fudan Univ, Shanghai Inst Cardiovasc Dis, Zhongshan Hosp, Shanghai, Peoples R China
[3] Fudan Univ, Natl Hlth Commiss Key Lab Viral Heart Dis, Shanghai, Peoples R China
[4] Chinese Acad Med Sci, Key Lab Viral Heart Dis, Shanghai, Peoples R China
[5] Rush Univ, Med Ctr, Div Cardiol, Chicago, IL 60612 USA
[6] Wenzhou Med Univ, Affiliated Hosp 1, Dept Cardiol, Key Lab Cardiovasc Dis Wenzhou, Wenzhou, Peoples R China
关键词
anatomical evaluation; canine model; conduction system pacing; electrocardiogram; His bundle pacing; left branch bundle pacing;
D O I
10.1111/jce.14300
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Left bundle branch pacing (LBBP), a form of conduction system pacing in addition to His bundle pacing (HBP), can potentially maintain left ventricular electrical synchrony with better sensing and a low and stable capture threshold. Methods We performed both HBP and LBBP using a canine model (n = 3; male; weight 30-40 kg). The electrocardiogram (ECG), intracardiac electrogram characteristics, and pacing parameters were compared between HBP and LBBP. The hearts were isolated and stained by Lugol's iodine (5%) to assess the relative locations of the leads in relation to the conduction system. Results The average potential to ventricle interval was longer with HBP compared to LBBP (26.67 +/- 3.06 ms vs 12.67 +/- 1.15 ms; P = .002). There were also notable differences in the pacing parameters between HBP and LBBP: R-wave amplitude (2.67 +/- 0.42 mV vs 11.33 +/- 3.06 mV; P = .008), pacing impedance (423.3 +/- 40.4 vs 660.0 +/- 45.8; P = .003), and threshold (2.30 +/- 0.66 V/0.4ms vs 0.67 +/- 0.15 V/0.4 ms; P = .014). The paced morphology of ECG was similar to the intrinsic with HBP while a right bundle branch block pattern was noted with LBBP. The anatomical evaluation revealed the location of the leads and the average lead depth was significantly more with LBBP as compared to HBP (12.33 +/- 1.53 mm vs1.83 +/- 0.29 mm; P < .0001). Furthermore, with LBBP, the tip of the lead helix was noted to be around the LBB. Conclusion This in vivo canine model study confirms the significant differences between HBP and LBBP. Furthermore, this model provides a precise anatomic evaluation of the location and the depth of the leads in relation to the conduction system.
引用
收藏
页码:214 / 219
页数:6
相关论文
共 25 条
  • [1] Abdelrahman M, 2018, J AM COLL CARDIOL, V71, P2581, DOI [10.1016/j.jacc.2018.02.048, 10.1016/S0735-1097(18)33122-X]
  • [2] Non-invasive electrocardiographic imaging of His-bundle and peri-left bundle pacing in left bundle branch block
    Chan, Joseph Yat Sun
    Huang, Wei Jian
    Yan, Bryan
    [J]. EUROPACE, 2019, 21 (06): : 837 - 837
  • [3] Comparison of electrocardiogram characteristics and pacing parameters between left bundle branch pacing and right ventricular pacing in patients receiving pacemaker therapy
    Chen, Keping
    Li, Yuqiu
    Dai, Yan
    Sun, Qi
    Luo, Bin
    Li, Chao
    Zhang, Shu
    [J]. EUROPACE, 2019, 21 (04): : 673 - 680
  • [4] The characteristics of the electrocardiogram and the intracardiac electrogram in left bundle branch pacing
    Chen, Xueying
    Wu, Shengjie
    Su, Lan
    Su, Yangang
    Huang, Weijian
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (07) : 1096 - 1101
  • [5] How to perform permanent His bundle pacing in routine clinical practice
    Dandamudi, Gopi
    Vijayaraman, Pugazhendhi
    [J]. HEART RHYTHM, 2016, 13 (06) : 1362 - 1366
  • [6] A beginner's guide to permanent left bundle branch pacing
    Huang, Weijian
    Chen, Xueying
    Su, Lan
    Wu, Shengjie
    Xia, Xue
    Vijayaraman, Pugazhendhi
    [J]. HEART RHYTHM, 2019, 16 (12) : 1791 - 1796
  • [7] Long-term outcomes of His bundle pacing in patients with heart failure with left bundle branch block
    Huang, Weijian
    Su, Lan
    Wu, Shengjie
    Xu, Lei
    Xiao, Fangyi
    Zhou, Xiaohong
    Mao, Guangyun
    Vijayaraman, Pugazhendhi
    Ellenbogen, Kenneth A.
    [J]. HEART, 2019, 105 (02) : 137 - 143
  • [8] A Novel Pacing Strategy With Low and Stable Output: Pacing the Left Bundle Branch Immediately Beyond the Conduction Block
    Huang, Weijian
    Su, Lan
    Wu, Shengjie
    Xu, Lei
    Xiao, Fangyi
    Zhou, Xiaohong
    Ellenbogen, Kenneth A.
    [J]. CANADIAN JOURNAL OF CARDIOLOGY, 2017, 33 (12) : 1736.e1 - 1736.e3
  • [9] Benefits of Permanent His Bundle Pacing Combined With Atrioventricular Node Ablation in Atrial Fibrillation Patients With Heart Failure With Both Preserved and Reduced Left Ventricular Ejection Fraction
    Huang, Weijian
    Su, Lan
    Wu, Shengjie
    Xu, Lei
    Xiao, Fangyi
    Zhou, Xiaohong
    Ellenbogen, Kenneth A.
    [J]. JOURNAL OF THE AMERICAN HEART ASSOCIATION, 2017, 6 (04):
  • [10] A NEW METHOD OF CONDUCTION SYSTEM STAINING
    ISHII, K
    KUROSAWA, H
    KOYANAGI, H
    KAWADA, M
    KOH, E
    SAKAKIBARA, N
    NAKANO, K
    IMAMURA, E
    KAIZUKA, H
    [J]. ANNALS OF THORACIC SURGERY, 1986, 42 (04) : 412 - 418