Osteoarthritis Index delivered by mobile phone (m-WOMAC) is valid, reliable, and responsive

被引:67
作者
Bellamy, Nicholas [1 ]
Wilson, Cecilia [1 ]
Hendrikz, Joan [1 ]
Whitehouse, Sarah L. [2 ,3 ,4 ,5 ]
Patel, Bipin [6 ]
Dennison, Simon [6 ]
Davis, Tim [6 ]
机构
[1] Univ Queensland, Ctr Natl Res Disabil & Rehabil Med CONROD, Brisbane, Qld 4006, Australia
[2] Prince Charles Hosp, Dept Orthoped Surg, Brisbane, Qld 4032, Australia
[3] Royal Brisbane & Womens Hosp, Dept Orthoped Surg, Brisbane, Qld 4006, Australia
[4] Mater Hosp, Dept Orthoped Surg, Brisbane, Qld 4101, Australia
[5] Queensland Univ Technol, Prince Charles Hosp, Inst Hlth & Biomed Innovat, Brisbane, Qld 4032, Australia
[6] Exco InTouch, Sawbridgeworth CM21 0AF, Herts, England
关键词
WOMAC; EDC; Osteoarthritis; Outcome measurement; PRO; Mobile phone; MCMASTER UNIVERSITIES OSTEOARTHRITIS; LEQUESNE-ALGOFUNCTIONAL INDEX; PERSONAL DIGITAL ASSISTANTS; PATIENT REPORTED OUTCOMES; WESTERN ONTARIO; HIP OSTEOARTHRITIS; CLINICAL-TRIALS; KNEE OSTEOARTHRITIS; RESPONDER CRITERIA; OA INDEX;
D O I
10.1016/j.jclinepi.2010.03.013
中图分类号
R19 [保健组织与事业(卫生事业管理)];
学科分类号
100404 [儿少卫生与妇幼保健学];
摘要
Objectives: To evaluate the validity, reliability, responsiveness, and mode preference of electronic data capture (EDC) using the Western Ontario and McMaster (WOMAC) numerical rating scale (NRS) 3.1 Osteoarthritis (OA) Index on Motorola V3 mobile phones. Study Design and Setting: Patients with OA undergoing hip or knee joint replacement were assessed preoperatively and 3-4 months postoperatively, completing the WOMAC Index in paper (p-WOMAC) and electronic (m-WOMAC) format in random order. Results: Data were successfully and securely transmitted from patients in Australia to a server in the United States. Pearson correlations between the summated total index scores (TISs) for the p-WOMAC and m-WOMAC pre- and postsurgery were 0.98 and 0.99 (P < 0.0001). There were no clinically important or statistically significant between-method differences in the adjusted total summated scores, pre- and postsurgery (adjusted mean differences = 4.44, P = 0.474 and 1.73, P = 0.781, respectively). Internal consistency estimates of m-WOMAC reliability were 0.87-0.98. The m-WOMAC detected clinically important, statistically significant (P < 0.0001) improvements in pain, stiffness, function, and TIS. No statistically significant differences in mode preference were detected. Conclusions: There was close agreement and no significant differences between m-WOMAC and p-WOMAC scores. This study confirms the validity, reliability, and responsiveness of the Exco InTouch-engineered, Java-based m-WOMAC Index application. EDC with the m-WOMAC Index provides unique opportunities for using quantitative measurement in clinical research and practice. (C) 2011 Elsevier Inc. All rights reserved.
引用
收藏
页码:182 / 190
页数:9
相关论文
共 49 条
[1]
ABASOMI A, 2006, AFR J MED SCI S, V35, P149
[2]
[Anonymous], PEW Global Attitudes Project
[3]
[Anonymous], GUID IND 11
[4]
[Anonymous], GSM WORLD
[5]
Assessment of postsurgical recovery after discharge using a pen computer diary [J].
Begg, A ;
Drummond, G ;
Tiplady, B .
ANAESTHESIA, 2003, 58 (11) :1101-1105
[6]
Osteoarthritis Measurement in Routine Rheumatology Outpatient Practice (OMIRROP) in Australia: A Survey of Practice Style, Instrument Use, Responder Criteria, and State-Attainment Criteria [J].
Bellamy, Elizabeth ;
Wilson, Cecilia ;
Bellamy, Nicholas .
JOURNAL OF RHEUMATOLOGY, 2009, 36 (05) :1049-1055
[7]
Bellamy N, 1997, J RHEUMATOL, V24, P2413
[8]
Bellamy N, 2007, ANN RHEUM DIS, V66, P491
[9]
Bellamy N, 2004, OSTEOARTHR CARTILAGE, V12, pS31
[10]
Bellamy N, 2004, OSTEOARTHR CARTILAGE, V12, pS69