Multi-component T1 relaxation and magnetisation transfer in peripheral nerve

被引:74
作者
Does, MD [1 ]
Beaulieu, C [1 ]
Allen, PS [1 ]
Snyder, RE [1 ]
机构
[1] Univ Alberta, Dept Biomed Engn, Edmonton, AB T6G 2G3, Canada
基金
英国医学研究理事会;
关键词
longitudinal relaxation; magnetisation transfer; peripheral nerve; myelin;
D O I
10.1016/S0730-725X(98)00139-8
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We report here a study of longitudinal relaxation (T-1) and magnetisation transfer (MT) in peripheral nerve. Amphibian sciatic nerve was maintained in vitro and studied at a magnetic field strength of 3 T, A CPMG pulse sequence was modified to include either a saturation pulse to measure T-1 relaxation or an off-resonance RF irradiation pulse to measure MT. The resulting transverse relaxation (T-2) spectra yielded four components corresponding to three nerve compartments, taken to result from myelinic, axonal, and inter-axonal water, and a fourth corresponding to the buffer solution water in which the nerve sample was bathed. Each nerve component was analysed for T-1 relaxation and MT. All three nerve T,components exhibited unique T-1 relaxation and MT characteristics, providing further support for the assignment of the components to unique physical compartments of water. Numerical investigation of T-1sat measurements of each of the three nerve T-2 components indicates that while the two shorter-lived exhibit similar steady-state magnetisation transfer ratios (MTRs), their respective MT properties are quite different, Simulations demonstrate that mobile water exchange between these two components is not necessary to explain their similar steady-state MTR. In the context of the assignment of these two components to signal from myelinic and axonal water, this is to say that these two microanatomical regions of nerve may exhibit similar steady-state MTR characteristics despite possessing widely different MT exchange rates. Therefore, interpreting changes in MTR solely to reflect a change in degree of myelination could lead to erroneous conclusions. (C) 1998 Elsevier Science Inc.
引用
收藏
页码:1033 / 1041
页数:9
相关论文
共 26 条
[1]  
BEAULIEU C, 1994, 2 ANN M SOC MAGN RES, P169
[2]  
Bevington R., 1969, DATA REDUCTION ERROR
[3]   T-2 RELAXATION OF PERIPHERAL-NERVE MEASURED IN-VIVO [J].
DOES, MD ;
SNYDER, RE .
MAGNETIC RESONANCE IMAGING, 1995, 13 (04) :575-580
[4]   Multiexponential T-2 relaxation in degenerating peripheral nerve [J].
Does, MD ;
Snyder, RE .
MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (02) :207-213
[5]   EXPERIMENTAL ALLERGIC ENCEPHALOMYELITIS AND MULTIPLE-SCLEROSIS - LESION CHARACTERIZATION WITH MAGNETIZATION TRANSFER IMAGING [J].
DOUSSET, V ;
GROSSMAN, RI ;
RAMER, KN ;
SCHNALL, MD ;
YOUNG, LH ;
GONZALEZSCARANO, F ;
LAVI, E ;
COHEN, JA .
RADIOLOGY, 1992, 182 (02) :483-491
[6]   QUANTITATIVE 2-DIMENSIONAL TIME CORRELATION RELAXOMETRY [J].
ENGLISH, AE ;
WHITTALL, KP ;
JOY, MLG ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1991, 22 (02) :425-434
[7]  
FENRICH FRE, 1991, 10TH P SMRM ANN M, P693
[8]  
GOUNOT D, 1995, 3 ANN M SOC MAGN RES, P1029
[9]   MAGNETIZATION-TRANSFER AND T-2 RELAXATION COMPONENTS IN TISSUE [J].
HARRISON, R ;
BRONSKILL, MJ ;
HENKELMAN, RM .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (04) :490-496
[10]   QUANTITATIVE INTERPRETATION OF MAGNETIZATION-TRANSFER [J].
HENKELMAN, RM ;
HUANG, XM ;
XIANG, QS ;
STANISZ, GJ ;
SWANSON, SD ;
BRONSKILL, MJ .
MAGNETIC RESONANCE IN MEDICINE, 1993, 29 (06) :759-766