The five percent electrode system for high-resolution EEG and ERP measurements

被引:1399
作者
Oostenveld, R
Praamstra, P
机构
[1] Univ Nijmegen Hosp, Inst Neurol, Dept Clin Neurophysiol, NL-6500 HB Nijmegen, Netherlands
[2] Univ Nijmegen, Dept Med & Biophys, Nijmegen, Netherlands
[3] Univ Birmingham, Behav Brain Sci Ctr, Birmingham, W Midlands, England
关键词
electrode placement; high resolution EEG; high resolution ERP; nomenclature;
D O I
10.1016/S1388-2457(00)00527-7
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Objective: A system for electrode placement is described. It is designed for studies on topography and source analysis of spontaneous and evoked EEG activity. Method: The proposed system is based on the extended International 10-20 system which contains 74 electrodes, and extends this system up to 345 electrode locations. Results: The positioning and nomenclature of the electrode system is described, and a subset of locations is proposed as especially useful for modern EEG/ERP systems, often having 128 channels available. Conclusion: Similar to the extension of the 10-20 system to the 10-10 system ('10% system'), proposed in 1985, the goal of this new extension to a 10-5 system is to further promote standardization in high-resolution EEG studies. (C) 2001 Elsevier Science Ireland Ltd. All rights reserved.
引用
收藏
页码:713 / 719
页数:7
相关论文
共 16 条
[1]  
[Anonymous], 1994, J Clin Neurophysiol, V11, P111
[2]  
Chatrian G. E., 1985, American Journal of EEG Technology, V25, P83
[3]   MODIFIED NOMENCLATURE FOR THE 10-PERCENT ELECTRODE SYSTEM [J].
CHATRIAN, GE ;
LETTICH, E ;
NELSON, PL .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 1988, 5 (02) :183-186
[4]   TOPOGRAPHY OF THE N400 - BRAIN ELECTRICAL-ACTIVITY REFLECTING SEMANTIC EXPECTANCY [J].
CURRAN, T ;
TUCKER, DM ;
KUTAS, M ;
POSNER, MI .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1993, 88 (03) :188-209
[5]   Imaging unconscious semantic priming [J].
Dehaene, S ;
Naccache, L ;
Le Clec'H, G ;
Koechlin, E ;
Mueller, M ;
Dehaene-Lambertz, G ;
van de Moortele, PF ;
Le Bihan, D .
NATURE, 1998, 395 (6702) :597-600
[6]  
Klem G H, 1999, Electroencephalogr Clin Neurophysiol Suppl, V52, P3
[7]   A rapid method for determining standard 10/10 electrode positions for high resolution EEG studies [J].
Le, J ;
Lu, M ;
Pellouchoud, E ;
Gevins, A .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 106 (06) :554-558
[8]   IFCN standards for digital recording of clinical EEG [J].
Nuwer, MR ;
Comi, G ;
Emerson, R ;
Fuglsang-Frederiksen, A ;
Guérit, JM ;
Hinrichs, H ;
Ikeda, A ;
Luccas, FJC ;
Rappelsburger, P .
ELECTROENCEPHALOGRAPHY AND CLINICAL NEUROPHYSIOLOGY, 1998, 106 (03) :259-261
[9]   RECORDING ELECTRODE SITE NOMENCLATURE [J].
NUWER, MR .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 1987, 4 (02) :121-133
[10]   The functional neuroanatomy of novelty processing: Integrating ERP and fMRI results [J].
Opitz, B ;
Mecklinger, A ;
Friederici, AD ;
von Cramon, DY .
CEREBRAL CORTEX, 1999, 9 (04) :379-391