Mechanism of recurrence after radiofrequency catheter ablation of atrial fibrillation guided by complex fractionated atrial electrograms

被引:12
作者
Crawford, Thomas C. [1 ]
Wimmer, Alan [1 ]
Dey, Sujoya [1 ]
Chalfoun, Nagib [1 ]
Wells, Darryl [1 ]
Sarrazin, Jean-Francois [1 ]
Kuhne, Michael [1 ]
Frederick, Melissa [1 ]
Jongnarangsin, Krit [1 ]
Good, Eric [1 ]
Chugh, Aman [1 ]
Bogun, Frank [1 ]
Pelosi, Frank, Jr. [1 ]
Morady, Fred [1 ]
Oral, Hakan [1 ]
机构
[1] Univ Michigan, Div Cardiovasc Med, Ann Arbor, MI 48109 USA
关键词
atrial fibrillation; ablation; radiofrequency; electrogram;
D O I
10.1007/s10840-007-9185-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background A better understanding of the mechanisms of recurrent atrial fibrillation (AF) after radiofrequency ablation of complex, fractionated atrial electrograms (CFAEs) may be helpful for refining AF ablation strategies. Methods and results Electrogram-guided ablation (EGA) was repeated in 30 consecutive patients (mean age = 59 +/- 8 years) for recurrent paroxysmal AF, 10 4 months after the first ablation. During the first procedure, CFAEs were targeted without isolating all pulmonary veins (PVs). During repeat ablation, all PVs and the superior vena cava (SVC) were mapped with a circular catheter and the left atrium was mapped for CFAEs. EGA was performed until AF was rendered noninducible or all identified CFAEs were eliminated. During repeat ablation, >= 1 PV tachycardia was found in 83 PVs in 29 of the 30 patients (97%). Among these 83 PVs, 63 (76%) had not been completely isolated previously. During repeat ablation, drivers originating in a PV or PV antrum were identified only after infusion of isoproterenol (20 mu g/min) in 12 patients (40%). At 9 4 months of follow-up after the repeat ablation procedure, 21 of the 30 patients (70%) were free from recurrent AF and flutter without antiarrhythmic drugs. Conclusions Recurrence of AF after EGA is usually due to PV tachycardias. Therefore, it may be preferable to systematically map and isolate all PVs during the first procedure. High-dose isoproterenol may be helpful to identify AF drivers.
引用
收藏
页码:27 / 33
页数:7
相关论文
共 23 条
[1]   Movement of the esophagus during left atrial catheter ablation for atrial fibrillation [J].
Good, E ;
Oral, H ;
Lemola, K ;
Han, J ;
Tamirisa, K ;
Igic, P ;
Elmouchi, D ;
Tschopp, D ;
Reich, S ;
Chugh, A ;
Bogun, F ;
Pelosi, F ;
Morady, F .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 46 (11) :2107-2110
[2]   Catheter ablation of long-lasting persistent atrial fibrillation:: Critical structures for termination [J].
Haïssaguerre, M ;
Sanders, P ;
Hocini, M ;
Takahashi, Y ;
Rotter, M ;
Sacher, F ;
Rostock, T ;
Hsu, LF ;
Bordachar, P ;
Reuter, S ;
Roudaut, R ;
Clémenty, J ;
Jaïs, P .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2005, 16 (11) :1125-1137
[3]   Changes in atrial fibrillation cycle length and inducibility during catheter ablation and their relation to outcome [J].
Haïssaguerre, M ;
Sanders, P ;
Hocini, M ;
Hsu, LF ;
Shah, DC ;
Scavée, C ;
Takahashi, Y ;
Rotter, M ;
Pasquié, JL ;
Garrigue, S ;
Clémenty, J ;
Jaïs, P .
CIRCULATION, 2004, 109 (24) :3007-3013
[4]   Spontaneous initiation of atrial fibrillation by ectopic beats originating in the pulmonary veins [J].
Haïssaguerre, M ;
Jaïs, P ;
Shah, DC ;
Takahashi, A ;
Hocini, M ;
Quiniou, G ;
Garrigue, S ;
Le Mouroux, A ;
Le Métayer, P ;
Clémenty, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (10) :659-666
[5]   Electrophysiological breakthroughs from the left atrium to the pulmonary veins [J].
Haïssaguerre, M ;
Shah, DC ;
Jaïs, P ;
Hocini, M ;
Yamane, T ;
Deisenhofer, I ;
Chauvin, M ;
Garrigue, S ;
Clémenty, J .
CIRCULATION, 2000, 102 (20) :2463-2465
[6]   Mother rotors and fibrillatory conduction: a mechanism of atrial fibrillation [J].
Jalife, J ;
Berenfeld, O ;
Mansour, M .
CARDIOVASCULAR RESEARCH, 2002, 54 (02) :204-216
[7]   Mechanisms of wave fractionation at boundaries of high-frequency excitation in the posterior left atrium of the isolated sheep heart during atrial fibrillation [J].
Kalifa, JM ;
Tanaka, K ;
Zaitsev, AV ;
Warren, M ;
Vaidyanathan, R ;
Auerbach, D ;
Pandit, S ;
Vikstrom, KL ;
Ploutz-Snyder, R ;
Talkachou, A ;
Atienza, F ;
Guiraudon, G ;
Jalife, J ;
Berenfeld, O .
CIRCULATION, 2006, 113 (05) :626-633
[8]  
Konings KTS, 1997, CIRCULATION, V95, P1231
[9]  
LEMOLA K, 2004, HEART RHYTHM, V1, pS10
[10]   Circular mapping and ablation of the pulmonary vein for treatment of atrial fibrillation - Impact of different catheter technologies [J].
Marrouche, NF ;
Dresing, T ;
Cole, C ;
Bash, D ;
Saad, E ;
Balaban, K ;
Pavia, SV ;
Schweikert, R ;
Saliba, W ;
Abdul-Karim, A ;
Pisano, E ;
Fanelli, R ;
Tchou, P ;
Natale, A .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2002, 40 (03) :464-474