Flow injection analysis capillary electrophoresis system with hydrodynamic injection

被引:46
作者
Kuban, P [1 ]
Pirmohammadi, R [1 ]
Karlberg, B [1 ]
机构
[1] Stockholm Univ, Dept Analyt Chem, S-10691 Stockholm, Sweden
关键词
flow injection analysis; capillary electrophoresis; hydrodynamic injection; inorganic cations;
D O I
10.1016/S0003-2670(98)00631-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow injection analysis-capillary electrophoresis (FIA-CE) system with hydrodynamic injection has been developed. Sample is injected in an electrolyte carrier solution pumped continuously in the FIA part of the system. The interface, connecting the FIA and the CE system moieties, accommodates one end of the separation capillary and a platinum electrode. The other capillary end and the second platinum electrode are immersed in a separate vial containing electrolyte solution. Carrier outflow from the interface is provided by a pinch valve. When the sample plug in the carrier passes the capillary end in the interface, the pinch valve is closed and a fraction of the sample is forced into the capillary. The high voltage supply, shut off during this sample introduction cycle, is then resumed and separation takes place in the capillary. Repeated sample injections in one electrophoretic run are facilitated. The overall repeatability, expressed as relative standard deviation for eight consecutive injections of 50 mg l(-1), was about 3%. Quantitative analyses can be accomplished ca. 5 times faster than that obtained using conventional CE instrumentation. The developed instrument was used to determine common inorganic cations (Na+, K+, Ca2+, Mg2+) in water and soft drink samples. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:55 / 62
页数:8
相关论文
共 15 条
[1]   Combination of flow injection with capillary electrophoresis. Part 3. On-line sorption column preconcentration capillary electrophoresis system [J].
Chen, HW ;
Fang, ZL .
ANALYTICA CHIMICA ACTA, 1997, 355 (2-3) :135-143
[2]  
Chien R. L., 1992, ANAL CHEM, V64, P489
[3]   ELECTRIC SAMPLE SPLITTER FOR CAPILLARY ZONE ELECTROPHORESIS [J].
DEML, M ;
FORET, F ;
BOCEK, P .
JOURNAL OF CHROMATOGRAPHY, 1985, 320 (01) :159-165
[4]   Combination of flow injection with capillary electrophoresis .1. The basic system [J].
Fang, ZL ;
Liu, ZS ;
Shen, Q .
ANALYTICA CHIMICA ACTA, 1997, 346 (02) :135-143
[5]   EVALUATION OF AN AUTOMATIC SIPHONIC SAMPLER FOR CAPILLARY ZONE ELECTROPHORESIS [J].
HONDA, S ;
IWASE, S ;
FUJIWARA, S .
JOURNAL OF CHROMATOGRAPHY, 1987, 404 (02) :313-320
[6]   BIAS IN QUANTITATIVE CAPILLARY ZONE ELECTROPHORESIS CAUSED BY ELECTROKINETIC SAMPLE INJECTION [J].
HUANG, XH ;
GORDON, MJ ;
ZARE, RN .
ANALYTICAL CHEMISTRY, 1988, 60 (04) :375-377
[7]  
KALJURAND M, 1995, HRC-J HIGH RES CHROM, V18, P263
[8]   Calibration principles for flow injection analysis-capillary electrophoresis systems with electrokinetic injection [J].
Kuban, P ;
Tennberg, K ;
Tryzell, R ;
Karlberg, B .
JOURNAL OF CHROMATOGRAPHY A, 1998, 808 (1-2) :219-227
[9]   On-line coupling of gas diffusion to capillary electrophoresis [J].
Kuban, P ;
Karlberg, B .
TALANTA, 1998, 45 (03) :477-484
[10]   New interface for coupling flow-injection and capillary electrophoresis [J].
Kuban, P ;
Engstrom, A ;
Olsson, JC ;
Thorsen, G ;
Tryzell, R ;
Karlberg, B .
ANALYTICA CHIMICA ACTA, 1997, 337 (02) :117-124