Encoding of anisotropic diffusion with tetrahedral gradients: A general mathematical diffusion formalism and experimental results

被引:244
作者
Conturo, TE [1 ]
McKinstry, RC [1 ]
Akbudak, E [1 ]
Robinson, BH [1 ]
机构
[1] UNIV WASHINGTON,DEPT CHEM,SEATTLE,WA 98195
关键词
MRI; diffusion; anisotropy; muscle;
D O I
10.1002/mrm.1910350319
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
A diffusion imaging method with a tetrahedral sampling pattern has been developed for high-sensitivity diffusion analysis. The tetrahedral gradient pattern consists of four different combinations of x, y, and z gradients applied simultaneously at full strength to uniformly measure diffusion in four different directions, Signal-to-noise can be increased by up to a factor of about three using this approach, compared with diffusion measurements made using separately applied x, y, and z gradients, A mathematical formalism is presented describing six fundamental parameters: the directionally averaged diffusion coefficient (D) over bar and diffusion element anisotropies eta and epsilon which are rotationally invariant, and diffusion ellipsoid orientation angles theta, phi, and psi which are rotationally variant, These six parameters contain all the information in the symmetric diffusion tensor D. Principal diffusion coefficients, reduced anisotropies, and other rotational invariants are further defined, It is shown that measurement of off-diagonal tensor elements is essential to assess anisotropy and orientation, and that the only parameter which can be measured with the orthogonal method is (D) over bar. In cases of axial diffusion symmetry (e.g., fibers), the four tetrahedral diffusion measurements efficiently enable determination of (D) over bar, eta, theta, and phi which contain all the diffusion information, From these four parameters, the diffusion parallel and perpendicular to the symmetry axis (D-parallel to and D-perpendicular to) and the axial anisotropy A can be determined, In more general cases, the six fundamental parameters can be determined with two additional diffusion measurements. Tetrahedral diffusion sequences were implemented on a clinical MR system, A muscle phantom demonstrates orientation independence of (D) over bar, D-parallel to, D-perpendicular to, and A for large changes in orientation angles, Sample background gradients and diffusion gradient imbalances were directly measured and found to be insignificant in most cases.
引用
收藏
页码:399 / 412
页数:14
相关论文
共 35 条
  • [1] Basser Peter J., 1995, P140
  • [2] MR DIFFUSION TENSOR SPECTROSCOPY AND IMAGING
    BASSER, PJ
    MATTIELLO, J
    LEBIHAN, D
    [J]. BIOPHYSICAL JOURNAL, 1994, 66 (01) : 259 - 267
  • [3] ESTIMATION OF THE EFFECTIVE SELF-DIFFUSION TENSOR FROM THE NMR SPIN-ECHO
    BASSER, PJ
    MATTIELLO, J
    LEBIHAN, D
    [J]. JOURNAL OF MAGNETIC RESONANCE SERIES B, 1994, 103 (03): : 247 - 254
  • [4] ANISOTROPIC DIFFUSION IN HUMAN WHITE MATTER - DEMONSTRATION WITH MR TECHNIQUES INVIVO
    CHENEVERT, TL
    BRUNBERG, JA
    PIPE, JG
    [J]. RADIOLOGY, 1990, 177 (02) : 401 - 405
  • [5] Cherry R J, 1978, Methods Enzymol, V54, P47
  • [6] MR DIFFUSION IMAGING OF THE HUMAN BRAIN
    CHIEN, D
    BUXTON, RB
    KWONG, KK
    BRADY, TJ
    ROSEN, BR
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (04) : 514 - 520
  • [7] NUCLEAR MAGNETIC-RESONANCE MEASUREMENT OF SKELETAL-MUSCLE - ANISOTROPY OF DIFFUSION-COEFFICIENT OF INTRACELLULAR WATER
    CLEVELAND, GG
    CHANG, DC
    HAZLEWOOD, CF
    RORSCHACH, HE
    [J]. BIOPHYSICAL JOURNAL, 1976, 16 (09) : 1043 - 1053
  • [8] CONTURO TE, 1991, P SMRM 10 ANN M SAN, P813
  • [9] CRANK J, 1975, MATH DIFFUSION, P6
  • [10] NORMAL AND ABNORMAL WHITE MATTER TRACTS SHOWN BY MR IMAGING USING DIRECTIONAL DIFFUSION WEIGHTED SEQUENCES
    DORAN, M
    HAJNAL, JV
    VANBRUGGEN, N
    KING, MD
    YOUNG, IR
    BYDDER, GM
    [J]. JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1990, 14 (06) : 865 - 873