A copolymerized dodecacarborane anion as covalently attached cation exchanger in ion-selective sensors

被引:49
作者
Qin, Y [1 ]
Bakker, E [1 ]
机构
[1] Auburn Univ, Dept Chem, Auburn, AL 36849 USA
关键词
D O I
10.1021/ac034447c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The traditional cation exchangers used in ion-selective electrodes and optodes are tetraphenylborate derivatives, which are generally adequate for most analytical applications but may in some cases suffer from decomposition by acid hydrolysis, oxidants, and light. Recently, halogenated dodecacarboranes were found to be improved cation exchangers in terms of lipophilicity and chemical stability. This forms the basis for the convenient covalent attachment of the cation exchanger to the polymeric backbone of the sensing material. This is a challenge that has not satisfactorily been solved and which is especially important in view of developing ultraminiaturized sensing arrays. Here, a C-derivative of the closo-dodecacarborane anion (CB11H12-) with a polymerizable group was synthesized as a chemically stable cation exchanger. This new derivative was copolymerized with methyl methacrylate and decyl methacrylate (MMA-DMA) to fabricate a plasticizer-free polymer with cation-exchange properties. This polymer could be conveniently blended with traditional plasticized poly(vinyl chloride) or with noncrosslinked methacrylic polymers to give solvent cast films that appear to be clear and homogeneous and that could be doped with ionophores. Optode leaching experiments supported the covalent grafting of the carborane anions. Ion-selective membranes and optode thin films were evaluated in terms of response function, response time, and selectivity. In all cases, the new material exhibited behavior similar to free tetraphenylborate derivative-based membranes. As a result of these studies, an all-polymeric plasticizer-free calcium-selective membrane was fabricated on the basis of the covalently attached carborane, a recently introduced grafted calcium ionophore, and an MMA-DMA polymer matrix. The resulting ion-selective electrodes showed Nernstian response slopes and rapid response times, demonstrating that covalent grafting of all sensing components is a feasible approach to the development of ion sensors.
引用
收藏
页码:6002 / 6010
页数:9
相关论文
共 52 条
[1]   TRITYL TETRAKIS(3,5-BIS(TRIFLUOROMETHYL)PHENYL)BORATE - A NEW HYDRIDE ABSTRACTION REAGENT [J].
BAHR, SR ;
BOUDJOUK, P .
JOURNAL OF ORGANIC CHEMISTRY, 1992, 57 (20) :5545-5547
[2]   SELECTIVITY OF ION-SENSITIVE BULK OPTODES [J].
BAKKER, E ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1805-1812
[3]   Determination of unbiased selectivity coefficients of neutral carrier-based cation-selective electrodes [J].
Bakker, E .
ANALYTICAL CHEMISTRY, 1997, 69 (06) :1061-1069
[4]   SYNTHESIS AND CHARACTERIZATION OF NEUTRAL HYDROGEN ION-SELECTIVE CHROMOIONOPHORES FOR USE IN BULK OPTODES [J].
BAKKER, E ;
LERCHI, M ;
ROSATZIN, T ;
RUSTERHOLZ, B ;
SIMON, W .
ANALYTICA CHIMICA ACTA, 1993, 278 (02) :211-225
[5]   Selectivity of potentiometric ion sensors [J].
Bakker, E ;
Pretsch, E ;
Bühlmann, P .
ANALYTICAL CHEMISTRY, 2000, 72 (06) :1127-1133
[6]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[7]   Plasticizer-free all-solid-state potassium-selective electrode based on poly(3-octylthiophene) and valinomycin [J].
Bobacka, J ;
Ivaska, A ;
Lewenstam, A .
ANALYTICA CHIMICA ACTA, 1999, 385 (1-3) :195-202
[8]   Fluorescent nanosensors for intracellular chemical analysis: Decyl methacrylate liquid polymer matrix and ion exchange-based potassium PEBBLE sensors with real-time application to viable rat C6 glioma cells [J].
Brasuel, M ;
Kopelman, R ;
Miller, TJ ;
Tjalkens, R ;
Philbert, MA .
ANALYTICAL CHEMISTRY, 2001, 73 (10) :2221-2228
[9]   Carrier-based ion-selective electrodes and bulk optodes. 2. Ionophores for potentiometric and optical sensors [J].
Buhlmann, P ;
Pretsch, E ;
Bakker, E .
CHEMICAL REVIEWS, 1998, 98 (04) :1593-1687
[10]   CHEMICAL SENSORS FOR BEDSIDE MONITORING OF CRITICALLY ILL PATIENTS [J].
COLLISON, ME ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1990, 62 (07) :A425-&