Bladder shape impact on the accuracy of ultrasonic estimation of bladder volume

被引:52
作者
Bih, LI
Ho, CC
Tsai, SJ
Lai, YC
Chow, W
机构
[1] Taichung Rehabil Hosp, Dept Rehabil Med, Taichung, Taiwan
[2] Chung Shan Med Coll, Dept Rehabil Med, Taichung, Taiwan
[3] Changhua Christian Hosp, Dept Rehabil Med, Changhua, Taiwan
[4] Chi Mei Fdn Hosp, Dept Rehabil Med, Tainan, Taiwan
来源
ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION | 1998年 / 79卷 / 12期
关键词
D O I
10.1016/S0003-9993(98)90419-1
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: Variations in bladder shape can lead to errors in ultrasonic estimation of the bladder volume. The purposes of this study were to compare the accuracies of various formulas to estimate bladder volume from sonographic measurements and to assess the impact of bladder shape on the accuracy of bladder volume estimation. Study design: Twenty-four healthy volunteers (13 men, 11 women) and 55 spinal cord injury patients (48 men, 7 women) underwent ultrasonographic measurements of dimensions before and after voiding. Bladder shape was classified as cuboid, ellipsoid, or triangular prism. Ten formulas from the literature were applied to estimate bladder volume, using the volume voided or catheterized as the standard, and then linear regression was used to obtain optimal correction coefficients for the whole data set as well as each of the three bladder shapes. Setting: Rehabilitation hospital affiliated with a medical college. Results: The most accurate of the 10 formulas tested was height (H) X transverse depth (Dt) X weight (W) X 0.7 (mean error 17.4% +/- 11.6%). Linear regression analysis yield optimal correction coefficients of .72 for the whole data set and .89, .81, and .66 for cuboidal, ellipsoid, and triangular prism-shaped bladders, respectively. The mean error for the estimation of bladder volume using .72 as the correction coefficient was 16.9% +/- 11.9% and decreased to 12.7% +/- 10.1% (p < .0001, paired t test) when the bladder shape was taken into account. Conclusion: Using bladder shape for reference and applying the corresponding correction coefficient to volume calculations will improve the accuracy of the estimation. (C) 1998 by the American Congress of Rehabilitation Medicine and the American Academy of Physical Medicine and Rehabilitation.
引用
收藏
页码:1553 / 1556
页数:4
相关论文
共 18 条
[1]   ULTRASOUND ASSESSMENT OF RESIDUAL URINE - A QUANTITATIVE METHOD [J].
BEACOCK, CJM ;
ROBERTS, EE ;
REES, RWM ;
BUCK, AC .
BRITISH JOURNAL OF UROLOGY, 1985, 57 (04) :410-413
[2]   ACCURACY OF ULTRASONIC BLADDER VOLUME MEASUREMENT IN CHILDREN [J].
BIS, KG ;
SLOVIS, TL .
PEDIATRIC RADIOLOGY, 1990, 20 (06) :457-460
[3]   APPLICATION OF OFFICE ULTRASOUND IN THE MANAGEMENT OF THE SPINAL-CORD INJURY PATIENT [J].
BODNER, DR ;
WITCHER, M ;
RESNICK, MI .
JOURNAL OF UROLOGY, 1990, 143 (05) :969-972
[4]   UROSONOGRAPHY IN SPINAL-CORD INJURY PATIENTS [J].
CALENOFF, L ;
NEIMAN, HL ;
KAPLAN, PE ;
NANNINGA, JB ;
BRANDT, TD ;
HAMILTON, BB ;
RESNICK, MI .
JOURNAL OF UROLOGY, 1982, 128 (06) :1234-1237
[5]   THE ESTIMATION OF BLADDER VOLUME BY SONOCYSTOGRAPHY [J].
HAKENBERG, OW ;
RYALL, RL ;
LANGLOIS, SL ;
MARSHALL, VR .
JOURNAL OF UROLOGY, 1983, 130 (02) :249-251
[6]  
HARRISON NW, 1976, BRIT J UROL, V47, P805
[7]   REAL-TIME ULTRASOUND MEASUREMENT OF BLADDER VOLUME - A COMPARATIVE-STUDY OF 3 METHODS [J].
HARTNELL, GG ;
KIELY, EA ;
WILLIAMS, G ;
GIBSON, RN .
BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (719) :1063-1065
[8]   RESIDUAL URINE VOLUME IN NORMAL MALE SUBJECTS [J].
HINMAN, F ;
COX, CE .
JOURNAL OF UROLOGY, 1967, 97 (04) :641-+
[9]   ULTRASONOGRAPHIC EVALUATION OF BLADDER VOLUME IN YOUNG-CHILDREN [J].
HIRAOKA, M ;
HORI, C ;
TSUCHIDA, S ;
SUDO, M .
PEDIATRIC NEPHROLOGY, 1995, 9 (03) :351-353
[10]   ULTRASONIC STUDIES OF BLADDER [J].
HOLMES, JH .
JOURNAL OF UROLOGY, 1967, 97 (04) :654-&