A custom three-dimensional electron bolus technique for optimization of postmastectomy irradiation

被引:66
作者
Perkins, GH
McNeese, MD
Antolak, JA
Buchholz, TA
Strom, EA
Hogstrom, KR
机构
[1] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Oncol, Houston, TX 77030 USA
[2] Univ Texas, MD Anderson Canc Ctr, Dept Expt Radiat Oncol, Houston, TX 77030 USA
[3] Univ Texas, MD Anderson Canc Ctr, Dept Radiat Phys, Houston, TX 77030 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 2001年 / 51卷 / 04期
关键词
postmastectomy irradiation; conformal electron therapy; electron bolus;
D O I
10.1016/S0360-3016(01)01744-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: Postmastectomy irradiation (PMI) is a technically complex treatment requiring consideration of the primary tumor location, possible risk of internal mammary node involvement, varying chest wall thicknesses secondary to surgical defects or body habitus, and risk of damaging normal underlying structures. In this report, we describe the application of a customized three-dimensional (3D) electron bolus technique for delivering PMI. Methods and Materials: A customized electron bolus was designed using a 3D planning system. Computed tomography (CT) images of each patient were obtained in treatment position and the volume to be treated was identified. The distal surface of the wax bolus matched the skin surface, and the proximal surface was designed to conform to the 90% isodose surface to the distal surface of the planning target volume (PTV). Dose was calculated with a pencil-beam algorithm correcting for patient heterogeneity. The bolus was then fabricated from modeling wax using a computer-controlled milling device. To aid in quality assurance, CT images with the bolus in place were generated and the dose distribution was computed using these images. Results: This technique optimized the dose distribution while minimizing irradiation of normal tissues. The use of a single anterior field eliminated field junction sites. Two patients who benefited from this option are described: one with altered chest wall geometry (congenital pectus excavatum), and one with recurrent disease in the medial chest wall and internal mammary chain (IMC) area. Conclusion: The use of custom 3D electron bolus for PMI is an effective method for optimizing dose delivery. The radiation dose distribution is highly conformal, dose heterogeneity is reduced compared to standard techniques in certain suboptimal settings, and excellent immediate outcome is obtained. (C) 2001 Elsevier Science Inc.
引用
收藏
页码:1142 / 1151
页数:10
相关论文
共 24 条
[1]  
ANTOLAK JA, 1994, 11 INT C US COMP RAD, P162
[2]   USE OF VARIABLE THICKNESS BOLUS TO CONTROL ELECTRON-BEAM PENETRATION IN CHEST WALL IRRADIATION [J].
ARCHAMBEAU, JO ;
FORELL, B ;
DORIA, R ;
FINDLEY, DO ;
JURISCH, R ;
JACKSON, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1981, 7 (06) :835-842
[3]  
BEACH JL, 1981, INT J RADIAT ONCOL, V7, P1607
[4]   RADIOTHERAPY FOR THE PREVENTION OF LOCAL-REGIONAL RECURRENCE IN HIGH-RISK PATIENTS POST MASTECTOMY RECEIVING ADJUVANT CHEMOTHERAPY [J].
FOWBLE, B ;
GLICK, J ;
GOODMAN, R .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 15 (03) :627-631
[5]   Postmastectomy radiotherapy: Toxicities and techniques to reduce them [J].
Hardenbergh, PH ;
Bentel, GC ;
Prosnitz, LR ;
Marks, LB .
SEMINARS IN RADIATION ONCOLOGY, 1999, 9 (03) :259-268
[6]  
Herbolsheimer M., 1994, Strahlentherapie und Onkologie, V170, P85
[7]   ELECTRON-BEAM DOSE CALCULATIONS [J].
HOGSTROM, KR ;
MILLS, MD ;
ALMOND, PR .
PHYSICS IN MEDICINE AND BIOLOGY, 1981, 26 (03) :445-459
[8]  
Janjan N A, 1989, Med Dosim, V14, P81
[9]   Electron density of tissues and breast cancer radiotherapy: A quantitative CT study [J].
Kalef-Ezra, JA ;
Karantanas, AH ;
Koligliatis, T ;
Boziari, A ;
Tsekeris, P .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (05) :1209-1214
[10]  
Lichter, 1992, Semin Radiat Oncol, V2, P94, DOI 10.1016/1053-4296(92)90013-B