Application of the electronic nose for uremia diagnosis

被引:90
作者
Lin, YJ
Guo, HR
Chang, YH
Kao, MT
Wang, HH
Hong, RI
机构
[1] Ind Technol Res Inst, Ctr Biomed Engn, Hsinchu, Taiwan
[2] China Med Coll Hosp, Taichung, Taiwan
[3] Natl Taiwan Univ, Dept Agr Chem, Taipei, Taiwan
关键词
electronic nose; uremia; breath analysis;
D O I
10.1016/S0925-4005(01)00625-6
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Breath analysis provides a way to diagnose diseases by detection of special odors in breaths; one of its clinical applications, electronic nose, has been proved as a non-invasive and rapid tool for diagnosis. In this study, a sensor module of the electronic nose is devised with six 12 MHz AT-cut quartz crystals array. probe peptides are designed with structure-based computer simulation, in which a simulated three-dimensional structure of the olfactory receptor protein (ORP) is docking with target gas molecules, and then synthesized. In the clinical test, this sensor module discriminates breaths from the normal subjects, patients with uremia, patients with chronic renal insufficiency (CRI) and patients with chronic renal failure (CRF) well by the discriminating analysis with a correct classification of 86.78%. In general, the normal subjects can be distinguished completely from the patients. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:177 / 180
页数:4
相关论文
共 8 条
[1]  
CHEN S, 1970, J LAB CLIN MED, V75, P628
[2]   Automated method for modeling seven-helix transmembrane receptors from experimental data [J].
Herzyk, P ;
Hubbard, RE .
BIOPHYSICAL JOURNAL, 1995, 69 (06) :2419-2442
[3]   A MOLECULAR MECHANICS GRID METHOD FOR EVALUATION OF LIGAND-RECEPTOR INTERACTIONS [J].
LUTY, BA ;
WASSERMAN, ZR ;
STOUTEN, PFW ;
HODGE, CN ;
ZACHARIAS, M ;
MCCAMMON, JA .
JOURNAL OF COMPUTATIONAL CHEMISTRY, 1995, 16 (04) :454-464
[4]  
MANOLIS A, 1983, CLIN CHEM, V29, P5
[5]  
Mason M F, 1976, J Forensic Sci, V21, P9
[6]   A novel method for diabetes diagnosis based on electronic nose [J].
Ping, W ;
Yi, T ;
Xie, HB ;
Shen, FR .
BIOSENSORS & BIOELECTRONICS, 1997, 12 (9-10) :1031-1036
[7]   MEASUREMENT OF VOLATILE ORGANIC-COMPOUNDS IN EXHALED BREATH AS COLLECTED IN EVACUATED ELECTROPOLISHED CANISTERS [J].
PLEIL, JD ;
LINDSTROM, AB .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 665 (02) :271-279
[8]   BIOCHEMICAL PROFILE OF UREMIC BREATH [J].
SIMENHOFF, ML ;
BURKE, JF ;
SAUKKONEN, JJ ;
ORDINARIO, AT ;
DOTY, R .
NEW ENGLAND JOURNAL OF MEDICINE, 1977, 297 (03) :132-135