Short-Circuit and Ground Fault Analyses and Location in VSC-Based DC Network Cables

被引:725
作者
Yang, Jin [1 ]
Fletcher, John E. [2 ]
O'Reilly, John [3 ]
机构
[1] Aston Univ, Sch Engn & Appl Sci, Birmingham B4 7ET, W Midlands, England
[2] Univ New S Wales, Sch Elect Engn & Telecommun, Sydney, NSW 2052, Australia
[3] Univ Glasgow, Dept Elect & Elect Engn, Glasgow G12 8LT, Lanark, Scotland
关键词
Fault analysis; fault location; multiterminal dc network; voltage-source converter (VSC); TRANSIENT OVERVOLTAGES; OVERCURRENT PROTECTION; LINE; AC;
D O I
10.1109/TIE.2011.2162712
中图分类号
TP [自动化技术、计算机技术];
学科分类号
080201 [机械制造及其自动化];
摘要
The application of high-power voltage-source converters (VSCs) to multiterminal dc networks is attracting research interest. The development of VSC-based dc networks is constrained by the lack of operational experience, the immaturity of appropriate protective devices, and the lack of appropriate fault analysis techniques. VSCs are vulnerable to dc-cable short-circuit and ground faults due to the high discharge current from the dc-link capacitance. However, faults occurring along the interconnecting dc cables are most likely to threaten system operation. In this paper, cable faults in VSC-based dc networks are analyzed in detail with the identification and definition of the most serious stages of the fault that need to be avoided. A fault location method is proposed because this is a prerequisite for an effective design of a fault protection scheme. It is demonstrated that it is relatively easy to evaluate the distance to a short-circuit fault using voltage reference comparison. For the more difficult challenge of locating ground faults, a method of estimating both the ground resistance and the distance to the fault is proposed by analyzing the initial stage of the fault transient. Analysis of the proposed method is provided and is based on simulation results, with a range of fault resistances, distances, and operational conditions considered.
引用
收藏
页码:3827 / 3837
页数:11
相关论文
共 32 条
[1]
Anderson P.M., 1999, Power system protection
[2]
[Anonymous], P IET 9 INT C DEV PO
[3]
[Anonymous], P POW EL SPEC C
[4]
[Anonymous], P IEEE PES AS PAC TR
[5]
[Anonymous], P IEEE PES AS PAC TR
[6]
DC distribution for industrial systems: Opportunities and challenges [J].
Baran, ME ;
Mahajan, NR .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2003, 39 (06) :1596-1601
[7]
Overcurrent protection on voltage-source-converter-based multiterminal DC distribution systems [J].
Baran, Mesut E. ;
Mahajan, Nikhil R. .
IEEE TRANSACTIONS ON POWER DELIVERY, 2007, 22 (01) :406-412
[8]
BASCOM EC, 1994, PROCEEDINGS OF THE 1994 IEEE POWER ENGINEERING SOCIETY TRANSMISSION AND DISTRIBUTION CONFERENCE, P376, DOI 10.1109/TDC.1994.328403
[9]
A new low-cost, fully fault-protected PWM-VSI inverter with true phase-current information [J].
Blaabjerg, F ;
Pedersen, JK .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1997, 12 (01) :187-197
[10]
HVDC connection of offshore wind farms to the transmission system [J].
Bresesti, Paola ;
Kling, Wil L. ;
Hendriks, Ralph L. ;
Vailati, Riccardo .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2007, 22 (01) :37-43