Dynamic delay and maximal dynamic error in continuous biosensors

被引:32
作者
Baker, DA [1 ]
Gough, DA [1 ]
机构
[1] UNIV CALIF SAN DIEGO, DEPT BIOENGN, LA JOLLA, CA 92093 USA
关键词
D O I
10.1021/ac960030d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
When biosensors are operated continuously, a dynamic delay and a dynamic error relate the sensor signal to the changing analyte concentration. The dynamic delay is the temporal displacement of the signal, or the lag, and is specified solely by properties of the biosensor and external mass transfer. The dynamic error is the difference between the actual concentration and the simultaneous reported concentration and is the product of the dynamic delay and the instantaneous rate of concentration change. In real-time operation of sensors, a maximal dynamic error based on the maximal expected rate of concentration change must be employed to estimate the worst-case error because the actual instantaneous rate is not independently known. Values of dynamic delay and maximal dynamic error that are acceptable in particular monitoring situations can be used in the design of acceptable continuous biosensors. This analysis suggests experimental alternatives to the standard response time approach for sensor characterization that are particularly advantageous for continuously operated biosensors. The concepts are applied here to in vitro operation of a continuous glucose sensor.
引用
收藏
页码:1292 / 1297
页数:6
相关论文
共 29 条
  • [1] [Anonymous], 1991, BIOSENSORS
  • [2] APPLICATION OF CHRONIC INTRAVASCULAR BLOOD-GLUCOSE SENSOR IN DOGS
    ARMOUR, JC
    LUCISANO, JY
    MCKEAN, BD
    GOUGH, DA
    [J]. DIABETES, 1990, 39 (12) : 1519 - 1526
  • [3] DYNAMIC CONCENTRATION CHALLENGES FOR BIOSENSOR CHARACTERIZATION
    BAKER, DA
    GOUGH, DA
    [J]. BIOSENSORS & BIOELECTRONICS, 1993, 8 (9-10) : 433 - 441
  • [4] COMMENTS ON THE RELATIONSHIP BETWEEN TIME-LAG AND DYNAMIC DELAY IN DIFFUSION-REACTION SYSTEMS
    BAKER, DA
    GOUGH, DA
    [J]. JOURNAL OF PHYSICAL CHEMISTRY, 1994, 98 (50) : 13432 - 13433
  • [5] Blum L.J., 1991, BIOSENSOR PRINCIPLES
  • [6] Braunwald E., 1987, HARRISONS PRINCIPLES
  • [7] CONWAY M, 1976, PEDIATRICS, V57, P244
  • [8] DRAPER CS, 1952, INSTRUMENT ENG, V3
  • [9] DIFFUSIONAL DISTORTION IN THE MONITORING OF DYNAMIC EVENTS
    ENGSTROM, RC
    WIGHTMAN, RM
    KRISTENSEN, EW
    [J]. ANALYTICAL CHEMISTRY, 1988, 60 (07) : 652 - 656
  • [10] PHYSIOLOGICAL PREPARATION FOR STUDYING THE RESPONSE OF SUBCUTANEOUSLY IMPLANTED GLUCOSE AND OXYGEN SENSORS
    ERTEFAI, S
    GOUGH, DA
    [J]. JOURNAL OF BIOMEDICAL ENGINEERING, 1989, 11 (05): : 362 - 368