Shah convolution differentiation Fourier transform for rear analysis in microchip capillary electrophoresis

被引:17
作者
Kwok, YC [1 ]
Manz, A [1 ]
机构
[1] Univ London Imperial Coll Sci Technol & Med, Dept Chem, AstraZeneca SmithKline Beecham Ctr Analyt Sci, London SW7 2AY, England
关键词
Shah convolution differentiation Fourier transform; chip technology; rear analysis; capillary electrophoresis; instrumentation; Fourier transform; rhodamine-110; chloride; fluorescein;
D O I
10.1016/S0021-9673(01)00989-X
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper first reports the application of Shah convolution differentiation Fourier transform for rear analysis. Rear analysis eliminates the need to create a well-defined and reproducible sample plug, thus making the operation simpler. The number of solution reservoirs, for microchip capillary electrophoresis (CE), could be reduced from the usual four to three. Sample bias in CE could be avoided too. The separation channel was first filled with the fluorescent sample solution, and subsequently flushed out with the buffer. The rear of each analyte zone gives rise to its flight of sigmoid-shaped steps in the time-domain. The time-domain detector signal was first differentiated and then Fourier transform was performed. The Fourier transform results were represented in the form of a magnitude plot. It is proposed that this would be as equally applicable to other separation techniques (e.g., chromatography) and detection methods (e.g., absorption). (C) 2001 Elsevier Science BV All rights reserved.
引用
收藏
页码:177 / 186
页数:10
相关论文
共 21 条
[1]  
[Anonymous], 2011, A Student's Guide to Fourier Transforms: With Applications in Physics and Engineering
[2]   Shah convolution Fourier transform detection [J].
Crabtree, HJ ;
Kopp, MU ;
Manz, A .
ANALYTICAL CHEMISTRY, 1999, 71 (11) :2130-2138
[3]   Lowering the UV absorbance detection limit in capillary zone electrophoresis using a single linear photodiode array detector [J].
Culbertson, CT ;
Jorgenson, JW .
ANALYTICAL CHEMISTRY, 1998, 70 (13) :2629-2638
[4]  
Culbertson CT, 1999, J MICROCOLUMN SEP, V11, P652, DOI 10.1002/(SICI)1520-667X(199911)11:9<652::AID-MCS3>3.3.CO
[5]  
2-Z
[6]   Deconvolution of overlapping chromatographic peaks by means of fast Fourier and Hartley transforms [J].
Economou, A ;
Fielden, PR ;
Packham, AJ .
ANALYST, 1996, 121 (02) :97-104
[7]   Ultrasensitive cross correlation electrophoresis on microchip devices [J].
Fister, JC ;
Jacobson, SC ;
Ramsey, JM .
ANALYTICAL CHEMISTRY, 1999, 71 (20) :4460-4464
[8]   Measurement of the binding of proteins to polyelectrolytes by frontal analysis continuous capillary electrophoresis [J].
Gao, JY ;
Dubin, PL ;
Muhoberac, BB .
ANALYTICAL CHEMISTRY, 1997, 69 (15) :2945-2951
[9]   MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP [J].
HARRISON, DJ ;
FLURI, K ;
SEILER, K ;
FAN, ZH ;
EFFENHAUSER, CS ;
MANZ, A .
SCIENCE, 1993, 261 (5123) :895-897
[10]   CAPILLARY ELECTROPHORESIS AND SAMPLE INJECTION SYSTEMS INTEGRATED ON A PLANAR GLASS CHIP [J].
HARRISON, DJ ;
MANZ, A ;
FAN, ZH ;
LUDI, H ;
WIDMER, HM .
ANALYTICAL CHEMISTRY, 1992, 64 (17) :1926-1932