Using fluorescence lifetime for discriminating detector afterpulsing in fluorescence-correlation spectroscopy

被引:93
作者
Enderlein, J [1 ]
Gregor, I [1 ]
机构
[1] Forschungszentrum Julich, Inst Biol Informat Proc 1 & 2, D-52425 Julich, Germany
关键词
D O I
10.1063/1.1863399
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Fluorescence correlation spectroscopy (FCS) has become an important and widely used technique for many applications in physics, chemistry, and biology. Usually, FCS is measured with sensitive light detectors working in the photon-counting Geiger mode. A common property of such detectors is afterpulsing: the generation of spurious photon detection events after a genuine photon detection. Such afterpulsing causes a significant deviation of the measured autocorrelation function from its true value on a short time scale and can seriously influence derived parameters for fast processes such as triplet-state photophysics. Here, we discuss the impact of afterpulsing on FCS in detail. A new method is developed to eliminate afterpulsing effects by using time-correlated single-photon counting for separating the true fluorescence signal from afterpulsing events. (C) 2005 American Institute of Physics.
引用
收藏
页数:5
相关论文
共 16 条
[1]   Time-resolved fluorescence correlation spectroscopy [J].
Böhmer, M ;
Wahl, M ;
Rahn, HJ ;
Erdmann, R ;
Enderlein, J .
CHEMICAL PHYSICS LETTERS, 2002, 353 (5-6) :439-445
[2]  
Böhmer M, 2001, REV SCI INSTRUM, V72, P4145, DOI 10.1063/1.1406926
[3]  
Bohmer M., 2002, Single Molecule Detection in Solution, P145, DOI [10.1002/3527600809.ch5, DOI 10.1002/3527600809.CH5]
[4]   FLUORESCENCE CORRELATION SPECTROSCOPY .1. CONCEPTUAL BASIS AND THEORY [J].
ELSON, EL ;
MAGDE, D .
BIOPOLYMERS, 1974, 13 (01) :1-27
[5]   Fast fitting of multi-exponential decay curves [J].
Enderlein, J ;
Erdmann, R .
OPTICS COMMUNICATIONS, 1997, 134 (1-6) :371-378
[6]   Biological and chemical applications of fluorescence correlation spectroscopy: A review [J].
Hess, ST ;
Huang, SH ;
Heikal, AA ;
Webb, WW .
BIOCHEMISTRY, 2002, 41 (03) :697-705
[7]  
HOBEL M, 1994, REV SCI INSTRUM, V65, P2326, DOI 10.1063/1.1144684
[8]   THE USE OF LEAST-SQUARES FOR XPS PEAK PARAMETERS ESTIMATION .1. MYTHS AND REALITIES [J].
LECLERC, G ;
PIREAUX, JJ .
JOURNAL OF ELECTRON SPECTROSCOPY AND RELATED PHENOMENA, 1995, 71 (02) :141-164
[9]   FLUORESCENCE CORRELATION SPECTROSCOPY .2. EXPERIMENTAL REALIZATION [J].
MAGDE, D ;
ELSON, EL ;
WEBB, WW .
BIOPOLYMERS, 1974, 13 (01) :29-61
[10]   THERMODYNAMIC FLUCTUATIONS IN A REACTING SYSTEM - MEASUREMENT BY FLUORESCENCE CORRELATION SPECTROSCOPY [J].
MAGDE, D ;
WEBB, WW ;
ELSON, E .
PHYSICAL REVIEW LETTERS, 1972, 29 (11) :705-&