Establishment of ANSI N13.11 X-ray radiation fields for personal dosimetry performance test by computation and experiment

被引:5
作者
Kim, JL
Kim, BH
Chang, SY
Lee, JK
机构
[1] Korea Atom Energy Res Inst, Dept Hlth Phys, Taejon, South Korea
[2] Han Yang Univ, Dept Nucl Engn, Seoul, South Korea
关键词
personal dosimetry; ANSI X-ray; spectrum calculation; spectrum measurement; average energy; conversion coefficients;
D O I
10.2307/3433642
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper describes establishment by computational and experimental methods of the American National Standard institute (ANSI) N13.11 X-ray radiation fields by the Korea Atomic Energy Research Institute (KAERI). These fields were used in the standard irradiations of various personal dosimeters for the personal dosimetry performance test program performed by the Ministry of Science and Technology of Korea in the autumn of 1995. Theoretical X-ray spectra produced from two KAERI X-ray generators were estimated using a modified Kramers' theory with target attenuation and backscatter correction and their spectral distributions experimentally measured by a high-purity germanium semiconductor detector through proper corrections for measured pulse height distributions with photopeak efficiency, Compton fraction, and K-escape fraction. The average energies and conversion coefficients obtained from the computation and experimental methods, when compared with ANSI N13.11 and the recently published National Institute of Standards and Technology X-ray beams, appeared to be in good agreement-+/-3% between corresponding values-and thus, could be satisfactorily applied in the performance test of personal dosimeters.
引用
收藏
页码:1417 / 1421
页数:5
相关论文
共 21 条
[1]  
*AM NAT STAND I, 1993, N13111193 ANSI STAND
[2]  
*AM NAT STAND I, 1983, N1311 ANSI STAND DEV
[3]  
[Anonymous], 1979, 4037 ISO
[4]   ELECTRON BACKSCATTERING FROM BULK MATERIALS [J].
ANTOLAK, AJ ;
WILLIAMSON, W .
JOURNAL OF APPLIED PHYSICS, 1985, 58 (01) :526-534
[5]   COMPUTATION OF BREMSSTRAHLUNG X-RAY-SPECTRA AND COMPARISON WITH SPECTRA MEASURED WITH A GE(LI) DETECTOR [J].
BIRCH, R ;
MARSHALL, M .
PHYSICS IN MEDICINE AND BIOLOGY, 1979, 24 (03) :505-517
[6]  
CHEN CT, 1984, ENERGY RESPONSE GE P
[7]  
GROSSWENDT B, 1990, RADIAT PROT DOSIM, V32, P219
[8]  
Grosswendt B., 1982, Radiation Protection Dosimetry, V3, P169
[9]   PHOTON MASS ATTENUATION AND ENERGY-ABSORPTION COEFFICIENTS FROM 1 KEV TO 20 MEV [J].
HUBBELL, JH .
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1982, 33 (11) :1269-1290
[10]  
*ICRP, 1987, ICRP, V51