Truth cube: Establishing physical standards for soft tissue simulation

被引:97
作者
Kerdok, AE
Cotin, SM
Ottensmeyer, MP
Galea, AM
Howe, RD
Dawson, SL
机构
[1] Harvard Univ, Div Engn & Appl Sci, Cambridge, MA 02138 USA
[2] Massachusetts Gen Hosp, CIMIT Simulat Grp, Boston, MA 02114 USA
关键词
physical standard; real-time models; model validation; soft tissue mechanics; surgical simulation;
D O I
10.1016/S1361-8415(03)00008-2
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Accurate real-time models of soft tissue behavior are key elements in medical simulation systems. The need for fast computation in these simulations, however, often requires simplifications that limit deformation accuracy. Validation of these simplified models remains a challenge. Currently, real-time modeling is at best validated against finite element models that have their own intrinsic limitations. This study develops a physical standard to validate real-time soft tissue deformation models. We took CT images of a cube of silicone rubber with a pattern of embedded Teflon spheres that underwent uniaxial compression and spherical indentation tests. The known material properties, geometry and controlled boundary conditions resulted in a complete set of volumetric displacement data. The results were compared to a finite element model analysis of identical situations. This work has served as a proof of concept for a robust physical standard for use in validating soft tissue models. A web site has been created to provide access to our database: http://biorobotics.harvard.edu/truthcube/ (soon to be http://www.truthcube.org). (C) 2003 Elsevier B.V. All rights reserved.
引用
收藏
页码:283 / 291
页数:9
相关论文
共 10 条
  • [1] [Anonymous], THESIS MIT CAMBRIDGE
  • [2] Bro-Nielsen M., 1996, EUROGRAPHICS 96, V15, P57
  • [3] Cotin S, 1996, ST HEAL T, V29, P139
  • [4] DELINGETTE H, 1998, IEEE SPECIAL ISSUE V, V86, P1
  • [5] Downes M, 1998, ST HEAL T, V50, P316
  • [6] The Karlsruhe endoscopic surgery trainer as an example for virtual reality in medical education
    Kuhnapfel, UG
    Kuhn, C
    Hubner, M
    Krumm, HG
    Maass, H
    Neisius, B
    [J]. MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 1997, 6 (02) : 122 - 125
  • [7] STRUMAS N, 1998, CAN J PLAST SURG, V6, P23
  • [8] Virtual reality-based simulation of endoscopic surgery
    Székely, G
    Brechbühler, C
    Dual, J
    Enzler, R
    Hug, J
    Hutter, R
    Ironmonger, N
    Kauer, M
    Meier, V
    Niederer, P
    Rhomberg, A
    Schmid, P
    Schweitzer, G
    Thaler, M
    Vuskovic, V
    Tröster, G
    Haller, U
    Bajka, M
    [J]. PRESENCE-VIRTUAL AND AUGMENTED REALITY, 2000, 9 (03): : 310 - 333
  • [9] WATERS K, 1992, SPIE P VBC 92
  • [10] WELLMAN PS, 1999, THESIS HARVARD U CAM