Fluorometric determination of microamounts of hydrogen peroxide with an immobilized enzyme prepared by coupling horseradish peroxidase to chitosan beads

被引:54
作者
Sakuragawa, A [1 ]
Taniai, T [1 ]
Okutani, T [1 ]
机构
[1] Nihon Univ, Coll Sci & Technol, Dept Ind Chem, Chiyoda Ku, Tokyo 101, Japan
关键词
hydrogen peroxide; fluorometric determination; immobilized enzyme; horseradish peroxidase; chitosan beads; p-(hydroxyphenyl)propionic acid as fluorescence substrate;
D O I
10.1016/S0003-2670(98)00469-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
It has been established that an immobilized enzyme which consists of chitosan beads as a carrier and horseradish peroxidase as an enzyme can be utilized for the determination of microamounts of hydrogen peroxide in environmental samples. The enzyme is immobilized on the carrier by a bridging method with glutaraldehyde; the immobilized reaction is simpler and involves milder condition compared with other immobilizing methods such as glass-amino beads. The immobilized enzyme was used for the fluorometric determination of hydrogen peroxide using 3-(p-hydroxyphenyl)propionic acid as fluorescent substrate by a batch method. The determination limit of the proposed method is about 50 ng cm(-3). The immobilized enzyme can be repeatedly employed for the determination of hydrogen peroxide. It can be used for seven days at least as long as it is stored at 4 degrees C in a preserving solution which is prepared using bovine serum albumin, sodium chloride and trishydroxymethylaminomethane. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:191 / 200
页数:10
相关论文
共 10 条
[1]   FLOW-INJECTION ANALYSIS FOR GLUCOSE AND UREA WITH ENZYME REACTORS AND ONLINE DIALYSIS [J].
GORTON, L ;
OGREN, L .
ANALYTICA CHIMICA ACTA, 1981, 130 (01) :45-53
[2]  
HAYASHI Y, 1985, ANAL SCI, V1, P65
[3]   IMMOBILIZED LUMINOL CHEMI-LUMINESCENCE REAGENT SYSTEM FOR HYDROGEN-PEROXIDE DETERMINATIONS IN FLOWING STREAMS [J].
HOOL, K ;
NIEMAN, TA .
ANALYTICAL CHEMISTRY, 1988, 60 (09) :834-837
[4]   SIMPLE AND RAPID SPECTROPHOTOMETRIC DETERMINATION OF IRON AFTER PRECONCENTRATION AS ITS 1,10-PHENANTHROLINE COMPLEX ON THE NATURAL POLYMER CHITIN [J].
HOSHI, S ;
YAMADA, M ;
INOUE, S ;
MATSUBARA, M .
TALANTA, 1989, 36 (05) :606-608
[5]   SPECTROPHOTOMETRIC DETERMINATION OF BISMUTH AFTER COLLECTION AND ELUTION OF ITS THIOUREA COMPLEX ON CHITIN [J].
HOSHI, S ;
NOTOYA, N ;
UTO, M ;
MATSUBARA, M .
ANALYTICAL SCIENCES, 1991, 7 (04) :657-660
[6]   Flow-injection determination of trace hydrogen peroxide or glucose utilizing an amperometric biosensor based on glucose oxidase bound to a reticulated vitreous carbon electrode [J].
Khayyami, M ;
Johansson, G ;
Kriz, D ;
Xie, B ;
Larsson, PO ;
Danielsson, B .
TALANTA, 1996, 43 (06) :957-962
[7]   HYDROGEN-PEROXIDE MEASUREMENT IN SEAWATER BY (PARA-HYDROXYPHENYL)ACETIC ACID DIMERIZATION [J].
MILLER, WL ;
KESTER, DR .
ANALYTICAL CHEMISTRY, 1988, 60 (24) :2711-2715
[8]   CHITIN AND CHITOSAN AS CHROMATOGRAPHIC SUPPORTS AND ADSORBENTS FOR COLLECTION OF METAL IONS FROM ORGANIC AND AQUEOUS SOLUTIONS AND SEA-WATER [J].
MUZZARELLI, RA ;
TUBERTINI, O .
TALANTA, 1969, 16 (12) :1571-+
[9]  
PUTTER J, 1974, METHOD ENZYMATIC ANA, V2
[10]   NEW FLUOROGENIC SUBSTRATES FOR HORSERADISH-PEROXIDASE - RAPID AND SENSITIVE ASSAYS FOR HYDROGEN-PEROXIDE AND THE PEROXIDASE [J].
ZAITSU, K ;
OHKURA, Y .
ANALYTICAL BIOCHEMISTRY, 1980, 109 (01) :109-113