Properties and performance of novel high-resolution/high-permeability ion-exchange media for protein chromatography

被引:49
作者
Martin, C [1 ]
Coyne, J [1 ]
Carta, G [1 ]
机构
[1] Univ Virginia, Dept Chem Engn, Charlottesville, VA 22904 USA
关键词
protein chromatography; monoliths; permeability; ion exchange;
D O I
10.1016/j.chroma.2004.08.114
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
There is continued interest in the development of stationary phases for protein chromatography that can provide high resolution at elevated flow rates of the mobile phase. When using porous particles, resolution and dynamic binding capacity decline rapidly as the flow rate is increased. Monolithic columns have been developed to overcome these limitations. However, there are difficulties in manufacturing homogeneous larger scale monoliths. In this paper we investigate the morphology and performance characteristics of columns based on new ion exchangers obtained by mechanically disrupting continuous beds of acrylamido-based polymeric media. Near colloidal suspensions of loose particles obtained with this procedure can be flow-packed in ordinary chromatography columns resulting in beds of unexpectedly high hydraulic permeability. Columns up to 2.2 cm in diameter were studied with both Q and S functionalized media. The hydraulic permeability and interparticle porosity of these columns were rather hi-h. The permeabilities of the S and Q media were 1.5 x 10(-13) and 2.4 x 10(-13) m(2) respectively, while the corresponding porosities were 60 and 70%. These porosity values are similar to those of monoliths, suggesting that these particles assemble under flow to give high-porosity bridged structures. The structure of these packed beds was further characterized by embedding small packed columns in resins and obtaining sections for microscopic observation. The sections reveal the presence of small aggregates of non-porous 1-3 mu m particles. surrounded by flow channels several micrometers in size. The height equivalent to a theoretical plate under isocratic and gradient elution conditions and the dynamic binding capacity were determined for several proteins and were found to be virtually independent of flow. (c) 2004 Elsevier B.V. All rights reserved.
引用
收藏
页码:43 / 52
页数:10
相关论文
共 27 条
[1]   FLOW-THROUGH PARTICLES FOR THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC SEPARATION OF BIOMOLECULES - PERFUSION CHROMATOGRAPHY [J].
AFEYAN, NB ;
GORDON, NF ;
MAZSAROFF, I ;
VARADY, L ;
FULTON, SP ;
YANG, YB ;
REGNIER, FE .
JOURNAL OF CHROMATOGRAPHY, 1990, 519 (01) :1-29
[2]  
[Anonymous], 1965, DYNAMICS CHROMATOGRA
[3]   Comparative study on the column performance of microparticulate 5-μm C18-bonded and monolithic C18-bonded reversed-phase columns in high-performance liquid chromatography [J].
Bidlingmaier, B ;
Unger, KK ;
von Doehren, N .
JOURNAL OF CHROMATOGRAPHY A, 1999, 832 (1-2) :11-16
[4]  
Bird R.B., 2006, TRANSPORT PHENOMENA, Vsecond, DOI 10.1002/aic.690070245
[5]   DIFFUSION AND CONVECTION IN CHROMATOGRAPHIC PROCESSES USING PERMEABLE SUPPORTS WITH A BIDISPERSE PORE STRUCTURE [J].
CARTA, G ;
RODRIGUES, AE .
CHEMICAL ENGINEERING SCIENCE, 1993, 48 (23) :3927-3935
[6]  
CARTA G, 1992, SEPAR TECHNOL, V2, P62, DOI DOI 10.1016/0956-9618(92)80008-2
[7]   Continuous-bed chromatography for the analysis and purification of recombinant human basic fibroblast growth factor [J].
Garke, G ;
Radtschenko, I ;
Anspach, FB .
JOURNAL OF CHROMATOGRAPHY A, 1999, 857 (1-2) :137-144
[8]   Peak broadening in protein chromatography with monoliths at very fast separations [J].
Hahn, R ;
Jungbauer, A .
ANALYTICAL CHEMISTRY, 2000, 72 (20) :4853-4858
[9]   Mass transfer properties of monoliths [J].
Hahn, R ;
Panzer, M ;
Hansen, E ;
Mollerup, J ;
Jungbauer, A .
SEPARATION SCIENCE AND TECHNOLOGY, 2002, 37 (07) :1545-1565