Short TE single-voxel 1H-MR spectroscopy of hippocampal structures in healthy adults at 1.5 Tesla -: how reproducible are the results?

被引:32
作者
Hammen, T [1 ]
Stadlbauer, A
Tomandl, B
Ganslandt, O
Pauli, E
Huk, W
Neundörfer, B
Stefan, H
机构
[1] Univ Erlangen Nurnberg, Dept Neurol, Ctr Epilepsy, D-8520 Erlangen, Germany
[2] Univ Erlangen Nurnberg, Neuroctr, D-8520 Erlangen, Germany
[3] Univ Erlangen Nurnberg, Dept Neurosurg, D-8520 Erlangen, Germany
[4] Univ Vienna, Dept Phys Med, NMR Grp, Vienna, Austria
[5] Univ Erlangen Nurnberg, Dept Neurosurg, Div Neuroradiol, Erlangen, Germany
关键词
magnetic resonance spectroscopy; H-1-MRS metabolite quantitation; LCModel; hippocampus; precision; inter- and intra-subject variability; reproducibility;
D O I
10.1002/nbm.958
中图分类号
Q6 [生物物理学];
学科分类号
071011 [生物物理学];
摘要
The purpose of our study was to evaluate inter- and intra-subject variability and scan-rescan reproducibility of single-voxel H-1-MR spectroscopy (H-1-MRS) in hippocampal structures at 1.5 T field strength. Thirty healthy adults were studied bilaterally by optimized, standardized short echo time single-voxel H-1-MRS (PRESS, TE = 30 ms, TR = 3000 ms, oblique voxel orientation, voxel size 2 cm(3)). Spectral analysis and absolute metabolite quantitation of N-acetylaspartate + N-acetylaspartyl-glutamate (tNAA), choline (Cho), creatine (Cr), total glutamate plus glutamine (Glu + Gln) and myo-inositol (Ins) were carried out by LCModel. Inter- and intra-individual reproducibility of these metabolite values were investigated by calculation of mean, standard deviation, coefficient of variation (CV), and by analysis of variance for repeated measurements. The smallest CV in intersubject variability was obtained for tNAA, followed by Cr, Cho, his and Glu + Gln. The results of the analysis of variance for repeated measures ill inter-subject variability showed a marginal effect of scan repetition for Cr (p = 0.063) and Glu + Gln (p=0.082); the rescan of both metabolites showed slightly higher concentrations. No statistical significant effect of scan repetition was seen for tNAA (p = 0.913), Cho (p = 0.857), and Ins (p = 0.826). Rescan led to the same results and gave proof of good reproducibility. Scan-rescan testing ill One Subject showed comparable results: tNAA (CV = 4.8%), followed by Cr, Ins, Glu + Gln and Cho (all CV above 10%). Copyright (c) 2005 John Wiley & Sons, Ltd.
引用
收藏
页码:195 / 201
页数:7
相关论文
共 32 条
[1]
Achten E, 1997, AM J NEURORADIOL, V18, P1131
[2]
QUANTITATION OF PROTON NMR-SPECTRA OF THE HUMAN BRAIN USING TISSUE WATER AS AN INTERNAL CONCENTRATION REFERENCE [J].
BARKER, PB ;
SOHER, BJ ;
BLACKBAND, SJ ;
CHATHAM, JC ;
MATHEWS, VP ;
BRYAN, RN .
NMR IN BIOMEDICINE, 1993, 6 (01) :89-94
[3]
ANALYSIS OF MACROMOLECULE RESONANCES IN H-1-NMR SPECTRA OF HUMAN BRAIN [J].
BEHAR, KL ;
ROTHMAN, DL ;
SPENCER, DD ;
PETROFF, OAC .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (03) :294-302
[4]
Brooks WM, 1999, MAGNET RESON MED, V41, P193, DOI 10.1002/(SICI)1522-2594(199901)41:1<193::AID-MRM27>3.0.CO
[5]
2-P
[6]
Normalization of neuronal metabolic dysfunction after surgery for temporal lobe epilepsy - Evidence from proton MR spectroscopic imaging [J].
Cendes, F ;
Andermann, F ;
Dubeau, F ;
Matthews, PM ;
Arnold, DL .
NEUROLOGY, 1997, 49 (06) :1525-1533
[7]
Choi CG, 1999, MAGNET RESON MED, V41, P204, DOI 10.1002/(SICI)1522-2594(199901)41:1<204::AID-MRM29>3.0.CO
[8]
2-7
[9]
Quantitative 1H MRS in the evaluation of mesial temporal lobe epilepsy in vivo [J].
Duc, CO ;
Trabesinger, AH ;
Weber, OM ;
Meier, D ;
Walder, R ;
Wieser, HG ;
Boesiger, P .
MAGNETIC RESONANCE IMAGING, 1998, 16 (08) :969-979
[10]
Analysis of 1.5 Tesla proton MR spectra of human brain using LCModel and an imported basis set [J].
Helms, G .
MAGNETIC RESONANCE IMAGING, 1999, 17 (08) :1211-1218