Reduced isoflurane consumption with bispectral index monitoring

被引:47
作者
Guignard, B [1 ]
Coste, C [1 ]
Menigaux, C [1 ]
Chauvin, M [1 ]
机构
[1] Hop Ambroise Pare, Dept Anaesthesia, F-92100 Boulogne, France
关键词
monitoring; bispectral analysis; anesthesia; depth; inhaled anesthetic; isoflurane; outcome; recovery; emergence time;
D O I
10.1034/j.1399-6576.2001.045003308.x
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Bispectral index (BIS) monitoring has been found to decrease the requirements for propofol, sevoflurane and desflurane and to improve recovery. We wanted to assess the effect of BIS monitoring on intraoperative isoflurane utilisation, and the early recovery profile. Methods: Eight; patients undergoing various surgical procedures were studied. In the first phase of the study, patients were anaesthetised without the use of BIS, the anaesthetists being blinded to the BIS readings, and isoflurane being administered according to standard clinical practice (control group). In a second phase, isoflurane was titrated to maintain a BIS value between 40 and 60 during surgery, and then 60-70 during 15 min prior to the end of surgery (BIS group). Isoflurane consumption was measured. Recovery times and the lime to achieve a modified Aldrete score of 9 were recorded. Results: Despite similar mean BIS levels during maintenance of anaesthesia, the cumulative time spent with BIS values between 40 and 60 during maintenance of anaesthesia was significantly longer in the BIS group as compared with the control group (P<0.001). The isoflurane usage in the BIS group was 12-25% lower than in the control group (P<0.05). The time to awakening and extubation were comparable in the two groups. Although the patients were less sedated (P<0.01) during the three post operative hours in the BIS (vs. control) group, no significant differences were observed in the time to obtain an Aldrete score of 9. Conclusion: The addition of BIS to standard monitoring decreases isoflurane consumption. However, we found only a small advantage in using BIS with respect to recovery from isoflurane anaesthesia.
引用
收藏
页码:308 / 314
页数:7
相关论文
共 15 条
[1]   THE POSTANESTHESIA RECOVERY SCORE REVISITED [J].
ALDRETE, JA .
JOURNAL OF CLINICAL ANESTHESIA, 1995, 7 (01) :89-91
[2]   CLINICAL COMPARISON OF SEVOFLURANE AND ISOFLURANE IN HEALTHY PATIENTS [J].
FRINK, EJ ;
MALAN, TP ;
ATLAS, M ;
DOMINGUEZ, LM ;
DINARDO, JA ;
BROWN, BR .
ANESTHESIA AND ANALGESIA, 1992, 74 (02) :241-245
[3]   Bispectral index monitoring allows faster emergence and improved recovery from propofol, alfentanil, and nitrous oxide anesthesia [J].
Gan, TJ ;
Glass, PS ;
Windsor, A ;
Payne, F ;
Rosow, C ;
Sebel, P ;
Manberg, P ;
Howell, S ;
Sanderson, I ;
Ray, J ;
Elidrissi, C ;
Wilkes, N ;
Calhoun, P ;
Connors, P ;
Alfille, P ;
Shapiro, L ;
Denman, W ;
Dershwitz, M ;
Clifford, J ;
Embree, P ;
Sigl, J .
ANESTHESIOLOGY, 1997, 87 (04) :808-815
[4]   Bispectral analysis measures sedation and memory effects of propofol, midazolam, isoflurane, and alfentanil in healthy volunteers [J].
Glass, PS ;
Bloom, M ;
Kearse, L ;
Rosow, C ;
Sebel, P ;
Manberg, P .
ANESTHESIOLOGY, 1997, 86 (04) :836-847
[5]   BISPECTRAL ANALYSIS OF THE ELECTROENCEPHALOGRAM CORRELATES WITH PATIENT MOVEMENT TO SKIN INCISION DURING PROPOFOL NITROUS-OXIDE ANESTHESIA [J].
KEARSE, LA ;
MANBERG, P ;
CHAMOUN, N ;
DEBROS, F ;
ZASLAVSKY, A .
ANESTHESIOLOGY, 1994, 81 (06) :1365-1370
[6]  
LASTER MJ, 1994, ANESTH ANALG, V78, P1152
[7]   PROPOFOL BLOOD-CONCENTRATION AND THE BISPECTRAL INDEX PREDICT SUPPRESSION OF LEARNING DURING PROPOFOL EPIDURAL-ANESTHESIA IN VOLUNTEERS [J].
LESLIE, K ;
SESSLER, DI ;
SCHROEDER, M ;
WALTERS, K .
ANESTHESIA AND ANALGESIA, 1995, 81 (06) :1269-1274
[8]  
Mapleson WW, 1996, BRIT J ANAESTH, V76, P179, DOI 10.1093/bja/76.2.179
[9]  
ROIZEN MF, 1994, ANESTH ANALG, V79, P410
[10]   A multicenter study of bispectral electroencephalogram analysis for monitoring anesthetic effect [J].
Sebel, PS ;
Lang, E ;
Rampil, IJ ;
White, PF ;
Cork, R ;
Jopling, M ;
Smith, NT ;
Glass, PSA ;
Manberg, P .
ANESTHESIA AND ANALGESIA, 1997, 84 (04) :891-899