New parameters of skin conductance compared with bispectral index® monitoring to assess emergence from total intravenous anaesthesia

被引:11
作者
Ledowski, T.
Preuss, J.
Ford, A.
Paech, M. J.
McTernan, C.
Kapila, R.
Schug, S. A.
机构
[1] Royal Perth Hosp, Dept Anaesthesia & Pain Med, Perth, WA 6000, Australia
[2] Univ Hosp Schleswig Holstein, Dept Anaesthesia & Intens Care Med, Kiel, Germany
[3] Univ Western Australia, Sch Med & Pharmacol, Perth, WA, Australia
关键词
anaesthetics i.v; monitoring; bispectral index; depth of anaesthesia; sympathetic nervous system;
D O I
10.1093/bja/aem189
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background. Arousal after total i.v. anaesthesia (TIVA) has been reported to be detectable by monitoring the number of fluctuations per second (NFSC), a parameter of skin conductance (SC). However, compared with monitoring of the bispectral index (BIS (R)), the predictive probability of NFSC was significantly lower. The aim of this study was to determine the value of the two new, not yet published parameters of SC, area under the curve (AUC) methods A and B, for monitoring emergence from TIVA compared with monitoring of NFSC and BIS (R). Methods. Twenty-five patients undergoing surgery were investigated. NFSC, AUC A, AUC B, BIS (R), and haemodynamic parameters (mean arterial pressure and heart rate) were recorded simultaneously. The performance of the monitoring devices in distinguishing between the clinical states 'steady-state anaesthesia', 'first clinical reaction', and 'extubation' were compared using the method of prediction probability (Pk) calculation. Results. 1360 showed the best performance in distinguishing between 'steady-state anaesthesia' vs 'first reaction' (Pk BIS (R) 0.95; NFSC 0.73; AUC A 0.54; AUC B 0.62) and 'steady-state anaesthesia' vs 'extubation' (Pk BIS (R) 0.99; NFSC 0.73; AUC A 0.71; AUC B 0.67). However, the time from first BlS((R))> 60/SC > 0 to a first clinical reaction was significantly shorter for BIS (R) (median BIS (R) 180 s; NFSC 780 s; AUC A 750 s; AUC B 690 s; P < 0.001). Conclusions. AUC A and AUC B did not improve accuracy of SC monitoring in patients waking after TIVA.
引用
收藏
页码:547 / 551
页数:5
相关论文
共 19 条
[1]  
[Anonymous], METHODS PSYCHOPHYSIO
[2]  
CHERNIK DA, 1990, J CLIN PSYCHOPHARM, V10, P244
[3]  
Critchley HD, 2000, J NEUROSCI, V20, P3033
[4]   Reduction in the incidence of awareness using BIS monitoring [J].
Ekman, A ;
Lindholm, ML ;
Lennmarken, C ;
Sandin, R .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2004, 48 (01) :20-26
[5]  
Ferguson SSG, 2001, PHARMACOL REV, V53, P1
[6]   Skin conductance or entropy for detection of non-noxious stimulation during different clinical levels of sedation [J].
Gjerstad, A. C. ;
Storm, H. ;
Hagen, R. ;
Huiku, M. ;
Qvigstad, E. ;
Raeder, J. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2007, 51 (01) :1-7
[7]   Comparison of skin conductance with entropy during intubation, tetanic stimulation and emergence from general anaesthesia [J].
Gjerstad, A. C. ;
Storm, H. ;
Hagen, R. ;
Huiku, M. ;
Qvigstad, E. ;
Raeder, J. .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2007, 51 (01) :8-15
[9]   Skin conductance as a measure of pain and stress in hospitalised infants [J].
Harrison, Denise ;
Boyce, Suzanne ;
Loughnan, Peter ;
Dargaville, Peter ;
Storm, Hanne ;
Johnston, Linda .
EARLY HUMAN DEVELOPMENT, 2006, 82 (09) :603-608
[10]   Rapid extraction of middle-latency auditory-evoked potentials [J].
Jensen, EW ;
Litvan, H .
ANESTHESIOLOGY, 2001, 94 (04) :718-718