Determination of linear alkylbenzenesulfonates and their degradation products in water samples by gas chromatography with ion-trap mass spectrometry

被引:41
作者
Ding, WH [1 ]
Lo, JH [1 ]
Tzing, SH [1 ]
机构
[1] Natl Cent Univ, Dept Chem, Chungli 32054, Taiwan
关键词
linear alkylbenzenesulfonates; sulfophenylcarboxylic acids;
D O I
10.1016/S0021-9673(98)00550-0
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method was developed for the analysis of Linear alkylbenzenesulfonates (LAS) and their degradation products, sulfophenylcarboxylic acids (SPC), in samples of sewage effluent and river water. This method involved extraction of the samples by graphitized carbon black cartridge, esterification by a two-step thionyl chloride-trifluoroethanol derivatization procedure, and separation, identification and quantitation by ion-trap CC-MS with EI and low pressure CT modes. High selectivity with few signals was observed in the low pressure CI mass spectra of LAS and SPC. Enhanced sensitivity with protonated molecular ion chromatograms of homologous C-10-C-13 LAS by CT-MS permit the determination of LAS and SPC at trace concentrations in environmental samples. Recovery rates of LAS and SPC in spiked water samples ranged from 75 to 112% with R.S.D, values from 3 to 26%. The limit of quantitation for both LAS and SPC was estimated to be 0.01 mu g/l in 100 ml of water sample. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:270 / 279
页数:10
相关论文
共 15 条
[1]   METHANE CHEMICAL IONIZATION OF PESTICIDES BY ION-TRAP TECHNOLOGY - SPECTRAL CHARACTERISTICS AND DATA PRECISION [J].
CAIRNS, T ;
CHIU, KS ;
SIEGMUND, E .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1992, 6 (05) :331-338
[2]   MONITORING AROMATIC SURFACTANTS AND THEIR BIODEGRADATION INTERMEDIATES IN RAW AND TREATED SEWAGES BY SOLID-PHASE EXTRACTION AND LIQUID-CHROMATOGRAPHY [J].
DICORCIA, A ;
SAMPERI, R ;
MARCOMINI, A .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1994, 28 (05) :850-858
[3]   QUANTITATIVE-DETERMINATION OF SULFONATED ALIPHATIC AND AROMATIC SURFACTANTS IN SEWAGE-SLUDGE BY ION-PAIR SUPERCRITICAL FLUID EXTRACTION AND DERIVATIZATION GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
FIELD, JA ;
MILLER, DJ ;
FIELD, TM ;
HAWTHORNE, SB ;
GIGER, W .
ANALYTICAL CHEMISTRY, 1992, 64 (24) :3161-3167
[4]  
LEE JF, 1993, EPA82E3G10909
[5]   REVERSED-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF LINEAR ALKYLBENZENE SULFONATES, NONYLPHENOL POLYETHOXYLATES AND THEIR CARBOXYLIC BIOTRANSFORMATION PRODUCTS [J].
MARCOMINI, A ;
DICORCIA, A ;
SAMPERI, R ;
CAPRI, S .
JOURNAL OF CHROMATOGRAPHY, 1993, 644 (01) :59-71
[6]  
MATTERN GC, 1991, J ASSOC OFF ANA CHEM, V74, P982
[7]   DETERMINATION OF SEVERAL PESTICIDES WITH A CHEMICAL IONIZATION ION TRAP DETECTOR [J].
MATTERN, GC ;
SINGER, GM ;
LOUIS, J ;
ROBSON, M ;
ROSEN, JD .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1990, 38 (02) :402-407
[8]   DETERMINATION OF LINEAR ALKYLBENZENESULFONATES IN SEWAGE-SLUDGE BY HIGH-RESOLUTION GAS-CHROMATOGRAPHY MASS-SPECTROMETRY [J].
MCEVOY, J ;
GIGER, W .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1986, 20 (04) :376-383
[9]  
MCLAFFERTY FW, 1993, INTERPRETATION MASS, P238
[10]   Determination of alkylbenzenesulfonates in recent sediments by gas chromatography mass spectrometry [J].
Reiser, R ;
Toljander, HO ;
Giger, W .
ANALYTICAL CHEMISTRY, 1997, 69 (23) :4923-4930