Kinetic determination of atrazine in foods based on stopped-flow fluorescence polarization immunoassay

被引:18
作者
Sendra, B
Panadero, S
Eremin, SA
Gomez-Hens, A
机构
[1] Univ Cordoba, Fac Sci, Dept Analyt Chem, E-14004 Cordoba, Spain
[2] Moscow MV Lomonosov State Univ, Dept Chem, Div Chem Enzymol, Moscow 119899, Russia
关键词
fluoroimmunoassay; kinetic method; atrazine; foods; stopped-flow mixing technique;
D O I
10.1016/S0039-9140(98)00064-2
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A very simple and fast method for the direct determination of atrazine in food samples based on the use of stopped-flow fluorescence polarization immunoassay is described. Unlike other immunoassay methods where the analytical signal is obtained when the immunochemical reaction has reached or is close to the equilibrium, this method uses the initial rate of this reaction as the analytical parameter, which is measured in only 4-5 s. This approach minimizes the static signal from the sample matrix, allows the direct analysis of the samples and can be easily adapted to the routine automatic determination of atrazine. The dynamic range of the calibration graph was 0.7-100 ng ml(-1) and the detection limit was 0.2 ng ml(-1). The precision and selectivity of the method were also studied. The analytical recoveries obtained by applying the method to white and red wine, orange juice and tea samples ranged from 80 to 104%. (C) 1998 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:153 / 160
页数:8
相关论文
共 24 条
[1]   Flow injection enzyme immunoassay of atrazine herbicide in water [J].
Bjarnason, B ;
Bousios, N ;
Eremin, SA ;
Johansson, G .
ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) :111-120
[2]   DETERMINATION OF ATRAZINE RESIDUES IN FOOD BY ENZYME-IMMUNOASSAY [J].
BUSHWAY, RJ ;
PERKINS, B ;
SAVAGE, SA ;
LEKOUSI, SL ;
FERGUSON, BS .
BULLETIN OF ENVIRONMENTAL CONTAMINATION AND TOXICOLOGY, 1989, 42 (06) :899-904
[3]  
BUSHWAY RJ, 1992, FOOD CHEM, V41, P283
[4]  
EREMIN SA, 1995, ACS SYM SER, V586, P223
[5]   DETERMINATION OF HYDROXY-S-TRIAZINES IN WATER USING HPLC OR GC-MS [J].
FARBER, H ;
NICK, K ;
SCHOLER, HF .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (03) :145-149
[6]   ENZYME IMMUNOASSAYS FOR S-TRIAZINE HERBICIDES AND THEIR APPLICATION IN ENVIRONMENTAL AND FOOD ANALYSIS [J].
FRANEK, M ;
KOLAR, V ;
EREMIN, SA .
ANALYTICA CHIMICA ACTA, 1995, 311 (03) :349-356
[7]   USE OF STOPPED-FLOW FLUORESCENCE POLARIZATION IMMUNOASSAY IN DRUG DETERMINATIONS [J].
GAIKWAD, A ;
GOMEZHENS, A ;
PEREZBENDITO, D .
ANALYTICA CHIMICA ACTA, 1993, 280 (01) :129-135
[8]   Development of a highly sensitive enzyme-linked immunosorbent assay for atrazine - Performance evaluation by flow injection immunoassay [J].
Gascon, J ;
Oubina, A ;
Ballesteros, B ;
Barcelo, D ;
Camps, F ;
Marco, MP ;
GonzalezMartinez, MA ;
Morais, S ;
Puchades, R ;
Maquieira, A .
ANALYTICA CHIMICA ACTA, 1997, 347 (1-2) :149-162
[9]   DETERMINATION OF ATRAZINE AND ALACHLOR IN NATURAL-WATERS BY A RAPID-MAGNETIC PARTICLE-BASED ELISA - INFLUENCE OF COMMON CROSS-REACTANTS - DEETHYLATRAZINE, DEISOPROPYLATRAZINE, SIMAZINE AND METOLACHLOR [J].
GASCON, J ;
MARTINEZ, E ;
BARCELO, D .
ANALYTICA CHIMICA ACTA, 1995, 311 (03) :357-364
[10]   HAPTEN SYNTHESIS, ANTIBODY DEVELOPMENT, AND COMPETITIVE-INHIBITION ENZYME-IMMUNOASSAY FOR S-TRIAZINE HERBICIDES [J].
GOODROW, MH ;
HARRISON, RO ;
HAMMOCK, BD .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 1990, 38 (04) :990-996