Experimental assessment of corneal Anisotropy

被引:86
作者
Elsheikh, Ahmed [1 ]
Brown, Michael [1 ]
Alhasso, Daad [1 ]
Rama, Paolo [2 ]
Campanelli, Marino [3 ]
Garway-Heath, David [4 ]
机构
[1] Univ Dundee, Div Civil Engn, Dundee DD1 4HN, Scotland
[2] Hosp San Raffaele, Dept Ophthalmol, Milan, Italy
[3] Monza Eye Bank, Monza, Italy
[4] UCL, Inst Ophthalmol, Moorfields Eye Hosp NHS Fdn Trust, NIHR Biomed Res Ctr Ophthalmol, London, England
关键词
D O I
10.3928/1081597X-20080201-09
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
PURPOSE: To determine the variation of corneal biomechanical properties with anatomical orientation. METHODS: Strip specimens extracted from fresh porcine corneas were tested under uniaxial tension with strain rates representing static and dynamic loading conditions. The specimens were extracted from the vertical, horizontal, and 45 degrees diagonal directions. The load elongation results were used to derive the stress-strain behavior of each specimen. The average behavior for specimens taken in each anatomical direction was determined along with the effect of strain rate. Specimens from a small number of human corneas were included in the study to verify the findings. RESULTS: Specimens extracted from the vertical direction of porcine and human corneas demonstrated the highest strength (fracture stress) followed by horizontal then diagonal specimens. Vertical specimens were 10% to 20% stronger than horizontal specimens in porcine and human corneas. At low strain rates (1%/min), vertical specimens displayed similar stiffness (resistance to deformation) to horizontal specimens but greater stiffness than diagonal specimens. On increasing the strain rate to 5000%/min, the stiffness behavior matched that of strength with vertical specimens being 10% to 20% stiffer than horizontal specimens in porcine and human corneas. CONCLUSIONS: The corneal anisotropic behavior is compatible with the preferential orientation of stromal fibrils in the vertical and horizontal directions. Quantifying the effect of this nonuniform fibril organization on corneal anisotropic behavior will be useful in developing numerical models of the cornea for applications Where its integrity is compromised such as in simulating refractive surgery procedures.
引用
收藏
页码:178 / 187
页数:10
相关论文
共 31 条
[1]
X-ray scattering used to map the preferred collagen orientation in the human cornea and limbus [J].
Aghamohammadzadeh, H ;
Newton, RH ;
Meek, KM .
STRUCTURE, 2004, 12 (02) :249-256
[2]
Preservation of canine and feline corneoscleral tissue in Optisol® GS [J].
Arndt, C ;
Reese, S ;
Köstlin, R .
VETERINARY OPHTHALMOLOGY, 2001, 4 (03) :175-182
[3]
Bergmanson Jan P G, 2005, Eye Contact Lens, V31, P281, DOI 10.1097/01.ICL.0000165280.94927.0D
[4]
Lamellar orientation in human cornea in relation to mechanical properties [J].
Boote, C ;
Dennis, S ;
Huang, YF ;
Quantock, AJ ;
Meek, KM .
JOURNAL OF STRUCTURAL BIOLOGY, 2005, 149 (01) :1-6
[5]
Constitutive laws for biomechanical modeling of refractive surgery [J].
Bryant, MR ;
McDonnell, PJ .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1996, 118 (04) :473-481
[6]
Daxer A, 1997, INVEST OPHTH VIS SCI, V38, P121
[7]
Human corneal thickness and its impact on intraocular pressure measures: A review and meta-analysis approach [J].
Doughty, MJ ;
Zaman, ML .
SURVEY OF OPHTHALMOLOGY, 2000, 44 (05) :367-408
[8]
Comparative study of corneal strip extensometry and inflation tests [J].
Elsheikh, A ;
Anderson, K .
JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2005, 2 (03) :177-185
[9]
Assessment of corneal biomechanical properties and their variation with age [J].
Elsheikh, Ahmed ;
Wang, Defu ;
Brown, Michael ;
Rama, Paolo ;
Campanelli, Marino ;
Pye, David .
CURRENT EYE RESEARCH, 2007, 32 (01) :11-19
[10]
Evaluation of goldmann applanation tonometry using a nonlinear finite element ocular model [J].
Elsheikh, Ahmed ;
Wang, Defu ;
Kotecha, Aachal ;
Brown, Michael ;
Garway-Heath, David .
ANNALS OF BIOMEDICAL ENGINEERING, 2006, 34 (10) :1628-1640