Radiation dose reduction to the male gonads during MDCT:: The effectiveness of a lead shield

被引:52
作者
Hohl, C
Mahnken, AH
Klotz, E
Das, M
Stargardt, A
Mühlenbruch, G
Schmidt, T
Günther, RW
Wildberger, JE
机构
[1] Rhein Westfal TH Aachen, Dept Diagnost Radiol, D-52057 Aachen, Germany
[2] Siemens Med Solut, Computed Technol, D-91301 Forchheim, Germany
关键词
D O I
10.2214/ajr.184.1.01840128
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. Our study was designed to quantify the effect of a standard gonad shield on the testicular radiation exposure due to scatter during routine abdominopelvic MDCT. SUBJECTS AND METHODS. Routine abdominopelvic MDCT was performed in 34 patients with gonadal lead shielding and 32 patients without this shielding; the testes were not exposed to the direct beam during the examination. We estimated the testicular dose administered with thermoluminescent dosimetry, taking into account each patient's body weight and body mass index (BMI). RESULTS. With a 1-mm lead shield, the mean testicular dose was reduced from 2.40 to 0.32 mSv, a reduction of 87%. The difference was found to be statistically significant (p < 0.0001). No correlation between testicular dose and body weight or BMI was found. CONCLUSION. Shielding the male gonads reduces the testicular radiation dose during abdominopelvic MDCT significantly and can be recommended for routine use.
引用
收藏
页码:128 / 130
页数:3
相关论文
共 7 条
[1]   In-plane bismuth breast shields for pediatric CT: Effects on radiation dose and image quality using experimental and clinical data [J].
Fricke, BL ;
Donnelly, LF ;
Frush, DP ;
Yoshizumi, T ;
Varchena, V ;
Poe, SA ;
Lucaya, J .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2003, 180 (02) :407-411
[2]  
German Federal Ministry for the Environment, 2002, NAT CONS NUCL SAF
[3]   Effectivity of lead aprons to reduce the radiation dose of patient in CT. [J].
Hidajat, N ;
Schroder, RJ ;
Vogl, T ;
Schedel, H ;
Felix, R .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1996, 165 (05) :462-465
[4]  
International Commission on Radiobiological Protection, 1991, REC INT COMM RAD PRO
[5]   Dose reduction during CT scanning in an anthropomorphic phantom by the use of a male gonad shield [J].
Price, R ;
Halson, P ;
Sampson, M .
BRITISH JOURNAL OF RADIOLOGY, 1999, 72 (857) :489-494
[6]   Dose reduction in CT: How low can we go? [J].
Rogers, LF .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2002, 179 (02) :299-299
[7]  
*ROY COLL RAD WORK, 2003, MAK BEST US DEP CLIN