Comparability of eight immunoassay procedures for the determination of CA 15-3 and related markers

被引:6
作者
Stern, P
Bartos, V
Vavrova, J
Bezdickova, D
Pechova, M
Uhrova, J
Friedecky, B
Sprongl, L
Zima, T
Palicka, V
机构
[1] Inst Postgrad Med Educ, Dept Clin Biochem, Prague, Czech Republic
[2] Charles Univ Prague, Gen Univ Hosp, Inst Clin Biochem & Lab Diagnost, Prague, Czech Republic
[3] Charles Univ Prague, Fac Med 1, Prague, Czech Republic
[4] Univ Ostrava, Univ Hosp Ostrava, Dept Nucl Med, CZ-70852 Ostrava, Czech Republic
[5] Univ Hosp, Inst Clin Chem & Diagnost, Hradec Kralove, Czech Republic
[6] Univ Hosp Motol, Inst Clin Chem & Pathobiochem, Prague, Czech Republic
关键词
CA; 15-3; immunoassays; comparability; heterogeneity; recovery; repeatability;
D O I
10.1515/CCLM.2003.168
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
MUC1 mucins are tumour markers that are frequently indicated and examined, particularly as part of the treatment of breast cancer. Relatively large differences were observed in external quality assessment (EQA) between the results that were obtained by different immunoassay technologies. Thus, we compared eight routinely employed immunoassay sets for the determination of MUC1 mucins in the serum: six closed automated systems (AxSYM, Centaur, ECi Vitros, Elecsys 2010, Immulite 2000 and Kryptor), and two IRMA kits (ELSA CIS and IRMA-mat Byk-Sangtec). Using all analytical systems, we measured identical groups of clinical samples complete with selected calibrator and control samples. The repeatability of measurements (presented as coefficients of variation) ranged from 0.7% (Kryptor) to 6.9% (Immulite 2000). Even though the cutoff values differ among various systems, no similar clinical efficacy appears to be attained. In the region of cutoff values, the highest specificity that was set as a standard was found for the AxSYM analyser, while the sensitivity was highest for the Elecsys 2010. Data from Bland-Altman differential plots suggest the presence of significant individual differences among individual samples, mainly in the region of high concentrations of MUC1 mucins. The parameters of Passing-Bablok regression show significant systematic differences between some of the analytical systems as well as an increase of the differences with increasing MUC1 mucin concentrations. The effect of the combination of antibodies used on the extent of differences among results obtained with individual systems is more obvious than the effect of the matrix of analysed materials.
引用
收藏
页码:1087 / 1094
页数:8
相关论文
共 18 条
[1]  
Bauer T, 2000, ANTICANCER RES, V20, P5245
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]  
Bon GG, 1997, CLIN CHEM, V43, P585
[4]  
Bruns DE, 2000, CLIN CHEM, V46, P893
[5]  
Cheli CD, 1998, CLIN CHEM, V44, P765
[6]   Effect of desialylation on binding, affinity, and specificity of 56 monoclonal antibodies against MUC1 mucin [J].
Dai, J ;
Allard, WJ ;
Davis, G ;
Yeung, KK .
TUMOR BIOLOGY, 1998, 19 :100-110
[7]   European symposium on clinical laboratory and in vitro diagnostics industry [J].
Dybkaer, R .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2001, 39 (05) :462-463
[8]  
Guarner J, 1997, ARCH MED RES, V28, P523
[9]  
Huber PR, 1996, EUR J CLIN CHEM CLIN, V34, P77
[10]  
Murray A, 1997, ANTICANCER RES, V17, P1945