Isotopic noble gas signatures released from medical isotope production facilities-Simulations and measurements

被引:70
作者
Saey, Paul R. J. [1 ]
Bowyer, Theodore W. [2 ]
Ringbom, Anders [3 ]
机构
[1] Vienna Univ Technol, Inst Atom, Austrian Univ, A-1020 Vienna, Austria
[2] Pacific NW Natl Lab, Richland, WA 99352 USA
[3] Swedish Def Res Agcy FOI, Def & Secur Syst & Technol Div, S-17290 Stockholm, Sweden
关键词
Uranium target irradiation; Medical isotopes; Low level radioxenon measurement; Environmental monitoring; Treaty verification; CTBTO;
D O I
10.1016/j.apradiso.2010.04.014
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Radioxenon isotopes play a major role in confirming whether or not an underground explosion was nuclear in nature. It is then of key importance to understand the sources of environmental radioxenon to be able to distinguish civil sources from those of a nuclear explosion. Based on several years of measurements, combined with advanced atmospheric transport model results, it was recently shown that the main source of radioxenon observations are strong and regular batch releases from a very limited number of medical isotope production facilities. This paper reviews production processes in different medical isotope facilities during which radioxenon is produced. Radioxenon activity concentrations and isotopic compositions are calculated for six large facilities. The results are compared with calculated signals from nuclear explosions. Further, the outcome is compared and found to be consistent with radioxenon measurements recently performed in and around three of these facilities. Some anomalies in measurements in which (131m)Xe was detected were found and a possible explanation is proposed. It was also calculated that the dose rate of the releases is well below regulatory values. Based on these results, it should be possible to better understand, interpret and verify signals measured in the noble gas measurement systems in the International Monitoring of the Comprehensive Nuclear-Test-Ban Treaty. (C) 2010 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1846 / 1854
页数:9
相关论文
共 26 条
[1]  
[Anonymous], 2000, NUREGCR0200 ORNL
[2]  
Ball R, 1999, 1065 IAEATECDOC, P5
[3]  
BONET H, 2005, P 9 INT TOP M RES RE
[4]   Detection and analysis of xenon isotopes for the comprehensive nuclear-test-ban treaty international monitoring system [J].
Bowyer, TW ;
Schlosser, C ;
Abel, KH ;
Auer, M ;
Hayes, JC ;
Heimbigner, TR ;
McIntyre, JI ;
Panisko, ME ;
Reeder, PL ;
Satorius, H ;
Schulze, J ;
Weiss, W .
JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2002, 59 (02) :139-151
[5]  
Dahlman O, 2009, NUCLEAR TEST BAN: CONVERTING POLITICAL VISIONS TO REALITY, pVII
[6]  
England T.R., 1994, LAUR943106 LOS AL NA
[7]   Changes in radioxenon observations in Canada and Europe during medical isotope production facility shut down in 2008 [J].
Hoffman, Ian ;
Ungar, Kurt ;
Bean, Marc ;
Yi, Jing ;
Servranckx, Rene ;
Zaganescu, Calin ;
Ek, Nils ;
Blanchard, Xavier ;
Le Petit, Gilbert ;
Brachet, Guy ;
Achim, Pascal ;
Taffary, Thomas .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2009, 282 (03) :767-772
[8]  
IAEA, 1989, 515 IAEATECDOC
[9]  
*IAEA, 2009, NUCL TECHN REV 2009, P46
[10]   Isotopic signature of atmospheric xenon released from light water reactors [J].
Kalinowski, Martin B. ;
Pistner, Christoph .
JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2006, 88 (03) :215-235