Relationship between polyethylene wear, pelvic osteolysis, and clinical symptomatology in patients with cementless acetabular components - A framework for decision making

被引:77
作者
Hozack, WJ [1 ]
Mesa, JJ [1 ]
Carey, C [1 ]
Rothman, RH [1 ]
机构
[1] THOMAS JEFFERSON UNIV,JEFFERSON MED COLL,DEPT ORTHOPAED SURG,PHILADELPHIA,PA 19107
关键词
pelvic osteolysis; total hip arthroplasty; revision; polyethylene wear;
D O I
10.1016/S0883-5403(96)80175-6
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study is to assess thr relationship between acetabular component polyethylene wear, pelvic osteolysis, and clinical symptoms to determine when operative intervention should occur and to predict the degree of difficulty of the revision. Fifty-four revisions of failed cementless acetabular components were performed in 52 patients. All cases demonstrated polyethylene wear radiographically and in 43 cases (80%), osteolysis of the pelvis was seen. Symptoms of groin or buttock pain were seen in 45 of 54 cases (83%). Preoperative staging of the disease process included one patient with wear radiographically but neither symptoms nor lysis (stage I), 10 patients with wear and pain (stage IIA), 8 patients with wear and lysis but no pain (stage IIB), and 35 patients with wear, lysis, and pain (stage III). Patients in stages I and IIA could be revised with cementless components without structural allograft. Patients in stages IIB and III required structural allograft in 79% and cemented components in 53%. Cemented components were used when there was less than 50% contact between host-bone and prosthesis. Polyethylene wear alone (stage I) is an indication of impending failure, and when symptoms develop (stage IIA), revision should be undertaken. The development of radiographic lysis is a critical event, and as soon as osteolysis develops (stage IIB or III), revision should be undertaken immediately. From the perspective or the revision surgeon, there is great value in the early intervention for polyethylene wear and pelvic osteolysis.
引用
收藏
页码:769 / 772
页数:4
相关论文
共 11 条
[1]   CATASTROPHIC FAILURE OF THE POLYETHYLENE LINER OF UNCEMENTED ACETABULAR COMPONENTS [J].
BERRY, DJ ;
BARNES, CL ;
SCOTT, RD ;
CABANELA, ME ;
POSS, R .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (04) :575-578
[2]   POLYETHYLENE WEAR IN CEMENTED METAL-BACKED ACETABULAR CUPS [J].
CATES, HE ;
FARIS, PM ;
KEATING, EM ;
RITTER, MA .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1993, 75 (02) :249-253
[3]  
DANTONIO JA, 1989, CLIN ORTHOP RELAT R, V243, P126
[4]  
HARRIS WH, 1995, CLIN ORTHOPAEDICS, V311, P46
[5]  
HERNANDEZ JR, 1994, J BONE JOINT SURG BR, V76B, P263
[6]   EFFECT OF FEMORAL-HEAD SIZE ON WEAR OF THE POLYETHYLENE ACETABULAR COMPONENT [J].
LIVERMORE, J ;
ILSTRUP, D ;
MORREY, B .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (04) :518-528
[7]   ENDOSTEAL EROSION IN ASSOCIATION WITH STABLE UNCEMENTED FEMORAL COMPONENTS [J].
MALONEY, WJ ;
JASTY, M ;
HARRIS, WH ;
GALANTE, JO ;
CALLAGHAN, JJ .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (07) :1025-1034
[8]   SEVERE OSTEOLYSIS OF THE PELVIS IN ASSOCIATION WITH ACETABULAR REPLACEMENT WITHOUT CEMENT [J].
MALONEY, WJ ;
PETERS, P ;
ENGH, CA ;
CHANDLER, H .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (11) :1627-1635
[9]   THE FEMORAL COMPONENT IN TOTAL HIP-ARTHROPLASTY - 6 TO 8-YEAR FOLLOW-UP OF 100 CONSECUTIVE PATIENTS AFTER USE OF A 3RD-GENERATION CEMENTING TECHNIQUE [J].
OISHI, CS ;
WALKER, RH ;
COLWELL, CW .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1994, 76A (08) :1130-1136
[10]   RESULTS OF UNCEMENTED POROUS-COATED ANATOMIC TOTAL HIP-REPLACEMENT [J].
OWEN, TD ;
MORAN, CG ;
SMITH, SR ;
PINDER, IM .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1994, 76B (02) :258-262