Determination of plasma, urine, and bovine serum albumin low-molecular-weight carbonyl levels by capillary gas chromatography with electron-capture and mass-selective detection

被引:19
作者
Konidari, CN
Giannopoulos, TS
Nanos, CG [1 ]
Stalikas, CD
机构
[1] Univ Ioannina, Dept Chem, Analyt Chem Lab, GR-45110 Ioannina, Greece
[2] Univ Ioannina, Dept Biol Applicat & Technol, GR-45110 Ioannina, Greece
关键词
low-molecular-weight carbonyl compounds; biological samples; 2,4,6-trichlorophenylhydrazine; gas chromatography;
D O I
10.1016/j.ab.2004.11.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Peroxidation of lipids produces low-molecular-weight carbonyl compounds, which are reactive with biological nucleophiles. The analysis of these compounds is often difficult. A multicomponent method for the determination of 11 of them in biological samples is reported. The samples are subjected to a pretreatment-derivatization procedure followed by gas chromatographic analysis with either electron-capture detection (ECD) or mass-selective detection (MSD) in the selected-ion monitoring mode. The procedure involves derivatization of the analyte with 2,4,6-trichlorophenylhydrazine, extraction with n-hexane, and separation of the derivatization products on a nonpolar gas chromatographic column. The concentration of the derivatization reagent, pH, reaction time, temperature, and presence of extraneous ions were investigated to determine the optimal derivatization conditions. Under these conditions, the method allows for the selective detection of low-molecular-weight carbonyl compounds at femtomole levels in several biological materials such as plasma, urine, and bovine serum albumin without interferences. The limits of detection were in the ranges 0.01-0.2 muM for ECD and 0.15-1.5 muM for MSD. The mean procedural recoveries obtained during the method validation were within the range 85-95% and the intra- and interassay standard deviations do not exceed 4.6 and 6.1%, respectively. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:62 / 70
页数:9
相关论文
共 38 条
[1]   A sensitive and reliable method for the detection of lipid peroxidation in biological tissues [J].
Anoopkumar-Dukie, S ;
Walker, RB ;
Daya, S .
JOURNAL OF PHARMACY AND PHARMACOLOGY, 2001, 53 (02) :263-266
[2]   UNEQUIVOCAL DEMONSTRATION THAT MALONDIALDEHYDE IS A MUTAGEN [J].
BASU, AK ;
MARNETT, LJ .
CARCINOGENESIS, 1983, 4 (03) :331-333
[3]   Malondialdehyde levels in serum of patients with skin cancer [J].
Bekerecioglu, M ;
Aslan, R ;
Ugras, S ;
Kutluhan, A ;
Sekeroglu, R ;
Akpolat, N ;
Karakok, M .
EUROPEAN JOURNAL OF PLASTIC SURGERY, 1998, 21 (05) :227-229
[4]   SUBPICOGRAM DETERMINATION OF MALONDIALDEHYDE BY GAS-LIQUID CHROMATOGRAPHY WITH NITROGEN PHOSPHORUS DETECTOR .1. STANDARDIZATION [J].
BELJEANLEYMARIE, M ;
BRUNA, E .
ANALYTICAL BIOCHEMISTRY, 1988, 173 (01) :174-184
[5]  
BRAY WE, 1962, BRAYS CLIN LAB METHO, P557
[6]   IS PENTANE A NORMAL CONSTITUENT OF HUMAN BREATH [J].
CAILLEUX, A ;
ALLAIN, P .
FREE RADICAL RESEARCH COMMUNICATIONS, 1993, 18 (06) :323-327
[7]   In search of biological markers of high-risk carotid artery atherosclerotic plaque: Enhanced LDL oxidation [J].
Chiesa, R ;
Melissano, G ;
Castellano, R ;
Astore, D ;
Marone, EM ;
Grossi, A ;
Maggi, E ;
Finardi, G ;
Casasco, A ;
Bellomo, G .
ANNALS OF VASCULAR SURGERY, 1998, 12 (01) :1-9
[8]   Free and total malondialdehyde assessment in biological matrices by gas chromatography mass spectrometry: What is needed for an accurate detection [J].
Cighetti, G ;
Debiasi, S ;
Paroni, R ;
Allevi, P .
ANALYTICAL BIOCHEMISTRY, 1999, 266 (02) :222-229
[9]   FREE MALONALDEHYDE DETERMINATION IN TISSUES BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
CSALLANY, AS ;
DERGUAN, M ;
MANWARING, JD ;
ADDIS, PB .
ANALYTICAL BIOCHEMISTRY, 1984, 142 (02) :277-283
[10]   GAS-CHROMATOGRAPHIC ANALYSIS OF REACTIVE CARBONYL-COMPOUNDS FORMED FROM LIPIDS UPON UV-IRRADIATION [J].
DENNIS, KJ ;
SHIBAMOTO, T .
LIPIDS, 1990, 25 (08) :460-464