Mechanism of cutting balloon angioplasty for in-stent restenosis: An intravascular ultrasound study

被引:8
作者
Montorsi, P [1 ]
Galli, S [1 ]
Fabbiocchi, F [1 ]
Loaldi, A [1 ]
Trabattoni, D [1 ]
Grancini, L [1 ]
Cozzi, S [1 ]
Ravagnani, P [1 ]
Parodi, O [1 ]
Bartorelli, AL [1 ]
机构
[1] Univ Milan, Inst Cardiol, Ctr Cardiol Monzino, IRCCS, I-20138 Milan, Italy
关键词
cutting balloon; in-stent restenosis; intravascular ultrasound;
D O I
10.1002/ccd.10191
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We investigated by intravascular ultrasound (IVUS) the mechanism of action of cutting balloon (CB) angioplasty in patients with in-stent restenosis. Seventy-one consecutive restenotic lesions of 66 patients were studied by quantitative coronary angiography (QCA) and IVUS before, immediately after, and, in 20 cases, at 24-hr time interval after CB. CB was selected according to 1:1 CB-to-stent ratio and inflated at 8 atm for 60-90 sec. Both IVUS planar and volumetric (Simpson's rule, 25 patients) analysis were carried out. IVUS measurements included external elastic membrane area (EEMA), stent area (SA), minimal lumen area (MLA), and restenosis area (RA). Following CB, OCA analysis showed increase of minimal lumen diameter (1.17 +/- 0.46 vs. 2.45 +/- 0.51 mm; P < 0.0001) and decrease of diameter stenosis (64% +/- 13% vs. 21% +/- 9%; P < 0.0001). IVUS measurements showed a significant increase of MLA (2.18 +/- 0.80 vs. 7.31 +/- 1.8 mm(2); p < 0.0001), SA (9.62 +/- 2.6 vs. 10.7 +/- 2.75 mm(2); p < 0.0001), and EEMA (117.27 +/- 5 vs. 18.1 +/- 5 mm(2); P < 0.0001) and a decrease of RA (7.43 +/- 2.63 vs. 3.45 +/- 1.39 mm(2); p < 0.0001). No significant change was observed in the original plaque + media area (7.65 +/- 3 vs. 7.38 +/- 2.9 mm(2); p = NS). Thus, of the total lumen enlargement (5.13 +/- 1.85 mm(2)), 23% was the result of increase in mean SA, whereas 77% was the result of a decrease in mean RA. These changes were associated with a 5% increase in EEMA. IVUS volumetric changes paralleled planar variations. Angiographic and IVUS changes were well maintained at 24 hr. CB enlarges coronary lumen mainly by in-stent tissue reduction associated with a moderate degree of additional stent expansion. Favorable QCA and IVUS acute results are maintained at 24 hr. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:166 / 173
页数:8
相关论文
共 35 条
[1]  
Adamian MG, 1999, CIRCULATION, V100, P305
[2]   Mechanism of lumen enlargement during intracoronary stent implantation - An intravascular ultrasound study [J].
Ahmed, JM ;
Mintz, GS ;
Weissman, NJ ;
Lansky, AJ ;
Pichard, AD ;
Satler, LF ;
Kent, KM .
CIRCULATION, 2000, 102 (01) :7-10
[3]  
Albiero R, 2000, CATHETER CARDIO INTE, V50, P452, DOI 10.1002/1522-726X(200008)50:4<452::AID-CCD19>3.0.CO
[4]  
2-W
[5]   MANAGEMENT OF RESTENOSIS WITHIN THE PALMAZ-SCHATZ CORONARY STENT (THE UNITED-STATES MULTICENTER EXPERIENCE) [J].
BAIM, DS ;
LEVINE, MJ ;
LEON, MB ;
LEVINE, S ;
ELLIS, SG ;
SCHATZ, RA .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 71 (04) :364-366
[6]   CUTTING BALLOON - A NOVEL-APPROACH TO PERCUTANEOUS ANGIOPLASTY [J].
BARATH, P ;
FISHBEIN, MC ;
VARI, S ;
FORRESTER, JS .
AMERICAN JOURNAL OF CARDIOLOGY, 1991, 68 (11) :1249-1252
[7]  
Bauters C, 1998, CIRCULATION, V97, P318
[8]  
Chevalier Bernard, 1999, Journal of the American College of Cardiology, V33, p62A
[9]   Mechanical debulking versus balloon angioplasty for the treatment of diffuse in-stent restenosis [J].
Dauerman, HL ;
Baim, DS ;
Cutlip, D ;
Sparano, AM ;
Gibson, CM ;
Kuntz, RE ;
Carrozza, JP ;
Garber, GR ;
Cohen, DJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 82 (03) :277-284
[10]  
Freitas Junior J O, 1999, Arq Bras Cardiol, V72, P615