Electrocatalytic oxidation and determination of insulin at CNT-nickel-cobalt oxide modified electrode

被引:78
作者
Arvinte, Adina [1 ]
Westermann, A. Caroline [1 ]
Sesay, Adama Marie [1 ]
Virtanen, Vesa [1 ]
机构
[1] Univ Oulu, Biotechnol Lab, Kajaani Univ Consortium, Sotkamo 88600, Kainuu, Finland
关键词
Nickel-cobalt oxide; CNT; Insulin oxidation; OXYGEN EVOLUTION; HYDROXIDE ELECTRODE; CARBON NANOTUBES; ELECTROCHEMICAL CAPACITORS; AMPEROMETRIC DETERMINATION; COMPOSITE ELECTRODES; PHYSIOLOGICAL PH; SPRAY-PYROLYSIS; METAL-OXIDES; THIN-FILMS;
D O I
10.1016/j.snb.2010.08.004
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
CNT-nickel-cobalt oxide/Nation composites were prepared by combining the nickel-cobalt oxide powder with CNT directly into the Nation solution used as a binder and deposited on screen-printed electrodes substrates Their electrochemical behaviour was investigated by means of cyclic voltammetry and amperometry techniques in NaOH and phosphate buffer solutions The electrocatalytic activity of these sensors was evaluated in terms of sensitivity detection limit and stability towards insulin detection CNT-nickel-cobalt oxide/Nation electrodes enable the oxidative detection of insulin in aqueous solution at physiological pH with a good sensitivity (22 57 mu A x mg(-1) x mL(-1)) An electrochemical activation step of the sensor in alkaline solution has been shown to be necessary for a three times more sensitive response of CNT-nickel-cobalt oxide-composite electrode toward insulin detection (c) 2010 Elsevier BV All rights reserved
引用
收藏
页码:756 / 763
页数:8
相关论文
共 50 条
[1]   SOME EFFECTS OF THE ADDITION OF COBALT TO THE NICKEL-HYDROXIDE ELECTRODE [J].
ARMSTRONG, RD ;
BRIGGS, GWD ;
CHARLES, EA .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 1988, 18 (02) :215-219
[2]  
BEHL WK, 1971, J ELECTROANAL CHEM, V31, P63, DOI 10.1016/S0022-0728(71)80043-8
[3]   Electrodeposited composite electrode materials: effect of the concentration of the electrocatalytic dispersed phase on the electrode activity [J].
Bertoncello, R ;
Furlanetto, F ;
Guerriero, P ;
Musiani, M .
ELECTROCHIMICA ACTA, 1999, 44 (23) :4061-4068
[4]   Amperometric detection of carbohydrates and thiols by using a glassy carbon electrode coated with Co oxide/multi-wall carbon nanotubes catalytic system [J].
Buratti, Susanna ;
Brunetti, Barbara ;
Mannino, Saverio .
TALANTA, 2008, 76 (02) :454-457
[5]   FORMATION OF HYDROUS OXIDE-FILMS ON COBALT UNDER POTENTIAL CYCLING CONDITIONS [J].
BURKE, LD ;
LYONS, ME ;
MURPHY, OJ .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1982, 132 (JAN) :247-261
[6]   THE INFLUENCE OF MATERIAL DISPERSION ON THE REDOX BEHAVIOR OF NICKEL-OXIDE ELECTRODES [J].
BURKE, LD ;
TWOMEY, TAM .
JOURNAL OF POWER SOURCES, 1984, 12 (3-4) :203-218
[7]   Preparation of mesoporous nanocrystalline Co3O4 and its applicability of porosity to the formation of electrochemical capacitance [J].
Cao, L ;
Lu, M ;
Li, HL .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2005, 152 (05) :A871-A875
[8]   COBALT-BASED GLASSY-CARBON CHEMICALLY MODIFIED ELECTRODE FOR CONSTANT-POTENTIAL AMPEROMETRIC DETECTION OF CARBOHYDRATES IN FLOW-INJECTION ANALYSIS AND LIQUID-CHROMATOGRAPHY [J].
CATALDI, TRI ;
CASELLA, IG ;
DESIMONI, E ;
ROTUNNO, T .
ANALYTICA CHIMICA ACTA, 1992, 270 (01) :161-171
[9]   Preparation of anodes for oxygen evolution by electrodeposition of composite Pb and Co oxides [J].
Cattarin, S ;
Guerriero, P ;
Musiani, M .
ELECTROCHIMICA ACTA, 2001, 46 (26-27) :4229-4234
[10]   Carbon electrodes modified with ruthenium metallodendrimer multilayers for the mediated oxidation of methionine and insulin at physiological pH [J].
Cheng, L ;
Pacey, GE ;
Cox, JA .
ANALYTICAL CHEMISTRY, 2001, 73 (22) :5607-5610