Flow cytometer for measurement of the light scattering of viral and other submicroscopic particles

被引:94
作者
Steen, HB [1 ]
机构
[1] Inst Canc Res, Dept Biophys, N-0310 Oslo, Norway
来源
CYTOMETRY PART A | 2004年 / 57A卷 / 02期
关键词
flow cytometry; light scattering measurement; submicroscopic particles; virus;
D O I
10.1002/cyto.a.10115
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Background: Light scattering is an essential parameter in flow cytometry, facilitating functions such as size measurement, discrimination of cell types on the basis of shape and morphology, detection of fluorescence-negative cells, and gating of fluorescence measurements. Light scattering measurement of viruses is generally not feasible with current flow cytometers due to their small size. The problem is aggravated by the fact that the light scattering of particles in this size range (<200 nm) falls off with roughly the sixth power of their linear dimensions. Methods: A new optical layout using darkfield illumination and detection has been developed. A 532-nm laser was used for excitation, and scattered light was collected with large aperture optics. Results: Light scattering histograms of polymer particles with diameters of 70-300 nm were recorded without gating by other parameters. By extrapolation, a detection limit of about 50 nm was obtained. Different species of virus with sizes of approximately 100 nm also were recorded. Conclusions: Flow cytometric light scattering measurement of Submicroscopic particles, in a size range that includes many viral species, is now feasible. The results indicate that it may be practically impossible to measure by flow cytometry the light scattering of particles smaller than 40 nm. (C) 2004 Wiley-liss, Inc.
引用
收藏
页码:94 / 99
页数:6
相关论文
共 10 条
[1]  
Adelberg, 1982, REV MED MICROBIOLOGY
[2]  
[Anonymous], FLOW CYTOMETRY SORTI
[3]   Flow cytometric detection of viruses [J].
Brussaard, CPD ;
Marie, D ;
Bratbak, G .
JOURNAL OF VIROLOGICAL METHODS, 2000, 85 (1-2) :175-182
[4]   DETECTION AND DISCRIMINATION OF INDIVIDUAL VIRUSES BY FLOW CYTOMETRY [J].
HERCHER, M ;
MUELLER, W ;
SHAPIRO, HM .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1979, 27 (01) :350-352
[5]  
Marie D, 1999, APPL ENVIRON MICROB, V65, P45
[6]   A sample injection device for flow cytometers [J].
Steen, HB .
CYTOMETRY, 2002, 49 (02) :70-72
[7]   SIMULTANEOUS SEPARATE DETECTION OF LOW-ANGLE AND LARGE-ANGLE LIGHT-SCATTERING IN AN ARC LAMP-BASED FLOW CYTOMETER [J].
STEEN, HB .
CYTOMETRY, 1986, 7 (05) :445-449
[8]   NOISE, SENSITIVITY, AND RESOLUTION OF FLOW CYTOMETERS [J].
STEEN, HB .
CYTOMETRY, 1992, 13 (08) :822-830
[9]  
STEEN HB, 1997, Patent No. 5684575
[10]  
Van de Hulst H. C., 1981, LIGHT SCATTERING SMA