Resorbable polymer fibers for ligament augmentation

被引:56
作者
Dürselen, L
Dauner, M
Hierlemann, H
Planck, H
Claes, LE
Ignatius, A
机构
[1] Univ Ulm, Inst Orthopaed Res & Biomech, D-89081 Ulm, Germany
[2] Inst Text Technol & Proc Engn, Denkendorf, Germany
来源
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH | 2001年 / 58卷 / 06期
关键词
resorbable polymer; fiber; ligament augmentation; poly(L -lactide); poly(L-lactide-co -glycolide);
D O I
10.1002/jbm.1067
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Resorbable augmentation devices for cruciate ligament surgery have been developed to temporarily protect healing tendon grafts or sutured ligaments against high tensile loads during the postoperative healing period. Materials available at present [e.g., polydioxanone (PDS)] show a half-life tensile strength of only 4-6 weeks, whereas the process of revitalization and recovering of the transplanted tendon graft can take up to 12 months. Therefore, a device that provides gradually decreasing mechanical properties with a half-time strength of at least 6 months would be desirable. In order to obtain a suitable material, we investigated the degradation kinetics of a variety of different resorbable fibers made of poly(L-lactide) and poly(L-lactide-co-glycolide). The fiber materials differed in processing and treatment parameters like thermal posttreatment, irradiation, and fiber diameter. The fibers were degraded in vitro and were tested for mechanical properties and molecular weight at various time points up to 72 weeks. The half-time strength of the materials ranged between 5 and 64 weeks, depending on their treatment parameters. In contrast, the stiffness did not decrease adequately. However, an augmentation stiffness that does not change much versus time could not provide a gradual increase in graft load, which is important to stimulate the orientation of the collagenous tissue. Therefore, design of an augmentation construct braided out of more than one quickly degrading fiber materials is suggested. After the breakdown of the faster-degrading fiber components the stiffness would automatically decrease by the diminution of the load-carrying fiber volume. (C) 2001 John Wiley & Sons, Inc.
引用
收藏
页码:666 / 672
页数:7
相关论文
共 29 条
[1]   PROCESSING AND CHARACTERIZATION OF ABSORBABLE POLYLACTIDE POLYMERS FOR USE IN SURGICAL IMPLANTS [J].
ANDRIANO, KP ;
POHJONEN, T ;
TORMALA, P .
JOURNAL OF APPLIED BIOMATERIALS, 1994, 5 (02) :133-140
[2]  
Bosch U, 1994, Acta Orthop Belg, V60 Suppl 1, P57
[3]   THE RELATIONSHIP OF MECHANICAL-PROPERTIES TO MORPHOLOGY IN PATELLAR TENDON AUTOGRAFTS AFTER POSTERIOR CRUCIATE LIGAMENT REPLACEMENT IN SHEEP [J].
BOSCH, U ;
DECKER, B ;
KASPERCZYK, W ;
NERLICH, A ;
OESTERN, HJ ;
TSCHERNE, H .
JOURNAL OF BIOMECHANICS, 1992, 25 (08) :821-830
[4]  
BOURNE RB, 1988, CAN J SURG, V31, P43
[5]   Augmentation of a ruptured posterior cruciate ligament provides normal knee joint stability during ligament healing [J].
Dürselen, L ;
Hehl, G ;
Simnacher, M ;
Kinzl, L ;
Claes, L .
CLINICAL BIOMECHANICS, 2001, 16 (03) :222-228
[6]   Biodegradable fibres of poly(L-lactic acid) produced by melt spinning [J].
Fambri, L ;
Pegoretti, A ;
Fenner, R ;
Incardona, SD ;
Migliaresi, C .
POLYMER, 1997, 38 (01) :79-85
[7]   BIODEGRADABLE FIBERS .1. POLY-L-LACTIC ACID FIBERS PRODUCED BY SOLUTION SPINNING [J].
FAMBRI, L ;
PEGORETTI, A ;
MAZZURANA, M ;
MIGLIARESI, C .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 1994, 5 (9-10) :679-683
[8]   Clinical experience with PDS II augmentation for operative treatment of acute proximal ACL ruptures - 2-year follow-up [J].
Hehl, G ;
Strecker, W ;
Richter, M ;
Kiefer, H ;
Wissmeyer, T .
KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 1999, 7 (02) :102-106
[9]  
Heino A, 1996, J BIOMED MATER RES, V30, P187, DOI 10.1002/(SICI)1097-4636(199602)30:2<187::AID-JBM8>3.0.CO
[10]  
2-N