A mini X-ray generator as an alternative to a 90Sr/90Y beta source in luminescence dating

被引:28
作者
Andersen, CE [1 ]
Botter-Jensen, L [1 ]
Murray, AS [1 ]
机构
[1] Aarhus Univ, Riso Natl Lab, Dept Earth Sci, Nord Lab Luminescence Dating, DK-4000 Roskilde, Denmark
关键词
X-ray; luminescence; OSL dating;
D O I
10.1016/S1350-4487(03)00022-2
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
We have carried out an investigation to test whether mini X-ray generators are a suitable alternative to radioactive sources in luminescence dating. The study has mainly been motivated by the need for high dose rates (similar to 1 Gy/s) to make dating of older samples using regeneration protocols more practical. Furthermore, X-ray generators are more suited for field work and work in countries where regulations restrict the use of radioactive sources. The system tested here (a 50 kV I mA Varian VF-50J tube with tungsten target and a matched Spellman high-voltage power supply) was found to provide: (i) excellent linearity between tube current (as set by the user on the control computer) and dose rate, (ii) a wide dynamic range: 2-30 mGy/s at 10 kV and 10-2000 mGy/s at 50 kV, (iii) short-term stability better than 0.2%, and (iv) a highly uniform irradiation of the sample area. Tests with a sample of thermally sensitized sedimentary quartz suggest that we can use beta and X-ray irradiation interchangeably from the point of view of construction of growth curves by the single-aliquot regenerative-dose protocol. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:557 / 561
页数:5
相关论文
共 7 条
[1]  
ANDERSEN CE, 2003, IN PRESS P INT S VIE
[2]  
ATTIX F. H., 1986, Introduction to radiological physics and radiation dosimetry
[3]   Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography [J].
Boone, JM ;
Fewell, TR ;
Jennings, RJ .
MEDICAL PHYSICS, 1997, 24 (12) :1863-1874
[4]   An automated system for both red/blue thermoluminescence and optically stimulated luminescence measurement [J].
Hashimoto, T ;
Nakagawa, T ;
Hong, DG ;
Takano, M .
JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2002, 39 (01) :108-109
[5]  
HELTHANSEN J, 2002, RISOESCAN 2 02 SOFTW
[6]   Luminescence dating of quartz using an improved single-aliquot regenerative-dose protocol [J].
Murray, AS ;
Wintle, AG .
RADIATION MEASUREMENTS, 2000, 32 (01) :57-73
[7]   The spatial variation of dose-rate from 90Sr/90Y beta sources for use in luminescence dating [J].
Spooner, NA ;
Allsop, A .
RADIATION MEASUREMENTS, 2000, 32 (01) :49-56