Position-sensitive germanium detectors for gamma-ray imaging and spectroscopy

被引:22
作者
Amman, M [1 ]
Luke, PN [1 ]
机构
[1] Univ Calif Berkeley, Ernest Orlando Lawrence Berkeley Natl Lab, Berkeley, CA 94720 USA
来源
HARD X-RAY GAMMA-RAY AND NEUTRON DETECTOR PHYSICS II | 2000年 / 4141卷
关键词
gamma-ray imaging; gamma-ray spectroscopy; germanium detector; position sensing; orthogonal strip;
D O I
10.1117/12.407575
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Gamma-ray imaging with position-sensitive germanium detectors offers the advantages of excellent energy resolution, high detection efficiency, and potentially good spatial resolution. The development of the amorphous-semiconductor electrical contact technology for germanium detectors has simplified the production of these position-sensitive detectors and has made possible the use of unique detection schemes and detector geometries. We have fabricated prototype orthogonal-strip detectors for gamma-ray imaging studies using this contact technology. With these detectors, we demonstrate that a gamma-ray interaction event in the detector can be located in three dimensions. This more accurate determination of the interaction event position should ultimately lead to better image resolution. We have also taken advantage of the bipolar blocking nature of the amorphous-semiconductor contacts in order to investigate the use of field-shaping electrodes. The addition of such electrodes is shown to improve the spectroscopic performance of the detectors by substantially eliminating charge collection to the inter-electrode surfaces. In addition, we demonstrate that this incomplete charge collection process can also be reduced by adjusting the properties of the amorphous-semiconductor layer. In this paper, we summarize the development of these position-sensitive detectors and present the results of our studies with the detectors.
引用
收藏
页码:144 / 156
页数:13
相关论文
共 29 条
[1]  
AMMAN M, IN PRESS NUCL INST A
[2]   CHARGE-TRANSPORT IN ARRAYS OF SEMICONDUCTOR GAMMA-RAY DETECTORS [J].
BARRETT, HH ;
ESKIN, JD ;
BARBER, HB .
PHYSICAL REVIEW LETTERS, 1995, 75 (01) :156-159
[3]  
Berger M.J., 1998, NIST Standard Reference Database (XGAM), V8, P87
[4]  
DETKO JF, 1973, MED RADIOISOTOPE SCI, P241
[5]   PHOTOMASK TECHNIQUE FOR FABRICATING HIGH-PURITY GERMANIUM STRIP DETECTORS [J].
GUTKNECHT, D .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 288 (01) :13-18
[6]   PERFORMANCE OF POSITION-SENSITIVE GERMANIUM DETECTORS IN NUCLEAR-REACTION EXPERIMENTS [J].
HAMACHER, A ;
MACHNER, H ;
NOLTE, M ;
PALARCZYK, M ;
PROTIC, D ;
RIEPE, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 295 (1-2) :128-132
[7]   AMORPHOUS-GERMANIUM AS AN ELECTRON OR HOLE BLOCKING CONTACT ON HIGH-PURITY GERMANIUM DETECTORS [J].
HANSEN, WL ;
HALLER, EE .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (01) :61-63
[8]   PROTECTIVE SURFACE-COATINGS ON SEMICONDUCTOR NUCLEAR RADIATION DETECTORS [J].
HANSEN, WL ;
HALLER, EE ;
HUBBARD, GS .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1980, 27 (01) :247-251
[9]   2-DETECTOR, 512-ELEMENT HIGH-PURITY GERMANIUM CAMERA PROTOTYPE [J].
KAUFMAN, L ;
LORENZ, V ;
HOSIER, K ;
HOENNINGER, J ;
HATTNER, RS ;
OKERLUND, M ;
PRICE, DC ;
SHAMES, DM ;
SWANN, SJ ;
EWINS, JH ;
ARMANTROUT, GA ;
CAMP, DC ;
LEE, K .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1978, 25 (01) :189-195
[10]   Charge spreading and position sensitivity in a segmented planar germanium detector [J].
Kroeger, RA ;
Gehrels, N ;
Johnson, WN ;
Kurfess, JD ;
Phlips, BP ;
Tueller, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3) :206-210