摘要
Fire safety of the new internal voids design for highrise buildings in Hong Kong was studied by covering three areas Fire in a room adjacent to the intemal void, including possibility of flashover and amount of smoke flowing out. Spread of smoke from the fire level to adjacent levels. Fire resistance provisions for windows. Fire models including application of computational fluid dynamics (CFD) are used for the analysis. CFD results indicated that there might be a potential fire hazard in this kind of design. Further studies should be carried out to investigate the problem. (C) 2003 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1317 / 1325
页数:9
相关论文
共 20 条
[1]  
*ASTM, 2000, ASTM E119 STAND TEST
[2]  
Babrauskas V., 1992, Heat Release in Fires
[3]  
*BRIT STAND I, 1987, BS 476 FIR TESTS 21
[4]  
*BRIT STAND I, 1987, BS 476 FIR TESTS 20
[5]  
Buildings Department, 1996, COD PRACT FIR RES CO
[6]  
*CHAM, 2000, PHOENICS VERS 3 1
[7]   Natural smoke filling in atrium with liquid pool fires up to 1.6 MW [J].
Chow, WK ;
Li, YZ ;
Cui, E ;
Huo, R .
BUILDING AND ENVIRONMENT, 2001, 36 (01) :121-127
[8]   Numerical studies of airflows induced by mechanical ventilation and air-conditioning (MVAC) systems [J].
Chow, WK .
APPLIED ENERGY, 2001, 68 (02) :135-159
[9]  
Drysdale D, 1999, INTRO FIRE DYNAMICS
[10]   FIRE DRAINAGE SYSTEM [J].
HARMATHY, TZ ;
OLESZKIEWICZ, I .
FIRE TECHNOLOGY, 1987, 23 (01) :26-48