A benchmark study with SealChip™ planar patch-clamp technology

被引:47
作者
Xu, J [1 ]
Guia, A [1 ]
Rothwarf, D [1 ]
Huang, MX [1 ]
Sithiphong, K [1 ]
Ouang, J [1 ]
Tao, GL [1 ]
Wang, XB [1 ]
Wu, L [1 ]
机构
[1] AVIVA Biosci Corp, San Diego, CA 92121 USA
关键词
D O I
10.1089/154065803770381039
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Although conventional patch-clamp methods provide high information content, they are labor-intensive and suffer from low throughput and high overall cost. Several approaches for achieving high throughput electrophysiology are under development, among which microchip-based patch-clamp systems uniquely achieve a higher degree of miniaturization, faster perfusion and mixing, and lower reagent cost without losing information content. The goal of this study was to establish a benchmark for our biochip technology with 52 chips tested sequentially. We demonstrate that our microfabrication and processing technology is sufficiently mature to produce a consistent hole size. We further demonstrate high-quality planar whole-cell patch clamping with >75% overall success rate at achieving gigaohm seals, followed by stable whole-cell access lasting at least 15 min with. access resistance (Ra) below 15 MOmega and membrane resistance (Rm) above 200 MOmega. These biochips are ideally suited for high throughput compound screening for ion channel targets.
引用
收藏
页码:675 / 684
页数:10
相关论文
共 16 条
[1]   Whole cell patch clamp recording performed on a planar glass chip [J].
Fertig, N ;
Blick, RH ;
Behrends, JC .
BIOPHYSICAL JOURNAL, 2002, 82 (06) :3056-3062
[2]   Microstructured glass chip for ion-channel electrophysiology [J].
Fertig, N. ;
Meyer, Ch. ;
Blick, R.H. ;
Trautmann, Ch. ;
Behrends, J.C. .
Physical Review E - Statistical, Nonlinear, and Soft Matter Physics, 2001, 64 (4 I) :409011-409014
[3]   IMPROVED PATCH-CLAMP TECHNIQUES FOR HIGH-RESOLUTION CURRENT RECORDING FROM CELLS AND CELL-FREE MEMBRANE PATCHES [J].
HAMILL, OP ;
MARTY, A ;
NEHER, E ;
SAKMANN, B ;
SIGWORTH, FJ .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1981, 391 (02) :85-100
[4]   ELECTRODE DESIGN FOR NEGATIVE DIELECTROPHORESIS [J].
HUANG, Y ;
PETHIG, R .
MEASUREMENT SCIENCE AND TECHNOLOGY, 1991, 2 (12) :1142-1146
[5]   High throughput ion-channel pharmacology: Planar-array-based voltage clamp [J].
Kiss, L ;
Bennett, PB ;
Uebele, VN ;
Koblan, KS ;
Kane, SA ;
Neagle, B ;
Schroeder, K .
ASSAY AND DRUG DEVELOPMENT TECHNOLOGIES, 2003, 1 (01) :127-135
[6]   Micromolded PDMS planar electrode allows patch clamp electrical recordings from cells [J].
Klemic, KG ;
Klemic, JF ;
Reed, MA ;
Sigworth, FJ .
BIOSENSORS & BIOELECTRONICS, 2002, 17 (6-7) :597-604
[7]  
Mattheakis L C, 2001, Curr Opin Drug Discov Devel, V4, P124
[8]   RECONSTITUTION OF CELL MEMBRANE STRUCTURE IN VITRO AND ITS TRANSFORMATION INTO AN EXCITABLE SYSTEM [J].
MUELLER, P ;
RUDIN, DO ;
TIEN, HT ;
WESCOTT, WC .
NATURE, 1962, 194 (4832) :979-&
[9]   RECONSTRUCTION OF REPOLARIZATION PROCESS IN CARDIAC PURKINJE FIBRES BASED ON VOLTAGE CLAMP MEASUREMENTS OF MEMBRANE CURRENT [J].
NOBLE, D ;
TSIEN, RW .
JOURNAL OF PHYSIOLOGY-LONDON, 1969, 200 (01) :233-+
[10]   Bilayer reconstitution of voltage-dependent ion channels using a microfabricated silicon chip [J].
Pantoja, R ;
Sigg, D ;
Blunck, R ;
Bezanilla, F ;
Heath, JR .
BIOPHYSICAL JOURNAL, 2001, 81 (04) :2389-2394